11.07.2015 Views

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

5 Construction Guidelines <strong>Tightening</strong> Technology | Bosch <strong>Rexroth</strong> AG 45/3165.3 Integration of the tightening system in an installationThe LC display shows:– OK/NOK evaluations– Numerical values of the tightening results– Display of errors5.3 Integration of the tightening system in an installation5.3.1 Ambient conditionsThe ambient conditions required for troublefree operation are found in the technical data of the “CS351”operating instructions, 3 609 929 B45.The system components comply with the following protection types:– Compact <strong>System</strong>: IP 54– ErgoSpin: IP 405.3.1.1 Constructive measures for maintaining the ambient conditionsATTENTION!Penetration of water and high humidityIf water or condensation penetrate, this may damage the CS351 Compact <strong>System</strong>.⇒ Penetration of water in the CS351 Compact <strong>System</strong> must be avoided at all costs.⇒ At higher humidities (>70%), constructive measures must be taken to prevent condensation.Switch cabinets with heaters are appropriate for this. A control with thermostats and hygrostatsis recommended.Ambient temperatureThe listed permissible ambient temperatures apply to installation heights up to 1000 m above MSL. Atgreater heights, the air pressure is lower, as well as the thermal conductivity, which results in a decreasein heat dissipation for the heat sinks.The required ambient temperature and maximum useable power for higher installation heights can be approximatedin the following diagram:100 %90 %K80 %70 %60 %50 %0 m1000 m 2000 m 3000 m 4000 mHFigure 5–3:Correction factor K of the maximum available power in dependence on the installation height H (above MSL)NoteThe ambient temperature may be lowered to counteract the reduction of the maximum available power athigh installation heights.5.3.1.2 <strong>Tightening</strong> <strong>System</strong> <strong>350</strong> temperature monitoring limitsThe temperature limit values (max. 45 °C) listed in the “CS351” operating instructions 3 609 929 B45apply when using the Compact <strong>System</strong>.<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!