11.07.2015 Views

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

10 Working with the <strong>System</strong> <strong>Tightening</strong> Technology | Bosch <strong>Rexroth</strong> AG 265/31610.1 Settings in the BS<strong>350</strong>10.1.9.2 Output and reset of the OK/NOK counterOutput on the LCD display in the CS351E-DOn the LC display, the counter readings for OK and NOK tightenings are output in the 3rd and 4th line,alternating with other values.TO K1 2 . 3 4Σ OK 4Σ N O K 1Figure 10–14: Output of counter readings from the active OK/NOK counter on the LCD displayIf a maximum value has been reached (control signal Ch x.y CntOK or Ch x.y CntNOK is output),the appropriate line will be inversely represented.If the control signal Ch x.y CntNOK is the result of a counter change, so the 4th line will be inverselyrepresented and a “C” for Cancel displayed between ΣNOK and the counter reading.Output on the TFT display in the CS351E-DOn the TFT display, counter readings are output in the standard display (Display → Standard) in the secondline and in the actual value display 2 (Display → Actual values 2) in the third line:Figure 10–15: Output of counter readings from the active OK/NOK counter on the TFT displayIf a maximum value has been reached (control signal Ch x.y CntOK or Ch x.y CntNOK is output),the reached count will be represented in red.If the control signal Ch x.y NOK has been caused by a counter change, the information from the NOKcounter will be represented in red and a “C” for Cancel displayed between NOK and the counter reading.Output in the BS<strong>350</strong>The counter readings of all active counters can be displayed in the BS<strong>350</strong> under <strong>System</strong> test → Infotightening cell → OK/NOK counter.Figure 10–16: Display of the counter readings of the OK/NOK counterDashes in the Actual column indicate that the counter is not active. A preceding “C” in the Actual columnindicates that the control signal Ch x.y CntNOK has been caused by a counter change.<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!