11.07.2015 Views

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

10 Working with the <strong>System</strong> <strong>Tightening</strong> Technology | Bosch <strong>Rexroth</strong> AG 301/31610.4 Results storage and statisticsThe name of the characteristic is made up of the source of the result and a characteristic abbreviationsuch as e.g.:– 0:T = target function Torque from the result step– 1:T = target function Torque from the step in docu buffer 1– 2:T = target function Torque from the step in docu buffer 2– 3:T = target function Torque from the step in docu buffer 3– 0:G = target function Gradient from the result stepThe entries in the Characteristics with intervention limits group field apply to all index cards. They onlybecome effective after another field is clicked on.ExampleUpper and lower angle monitoring limits have been set in the tightening program to A+: 1000° and A–:850°. The above values (95/105%) result in an upper intervention limit of 950° and a lower one of892.5°.10.4.7.2 Results index cardFigure 10–63: Results index cardThe tightening results loaded from the tightening controller results storage are listed in the Results indexcard. The data organized into columns is only determined by the chosen configuration of the results storage(see page 295).Each column can be separately filtered in the Results index card for further data evaluation by selectingthe symbol. The following types of filters are used in the Results index card:– Selection From: ... To ...:Data records within the From: ... To ...: range are processed (e.g. consecutive number from 32 to 82)– Selection with a matrix:Data records for the selected values are processed (e.g. program number 99 and 0).– Compare:Data records with the same value as that entered are processed (e.g. quality code QC1).– List:Data records with selected conditions will be processed (e.g. OK results).The arrow in theas standard.symbol will appear in blue if the filter is activated. All filters are inactive (black arrow)<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!