11.07.2015 Views

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

254/316 Bosch <strong>Rexroth</strong> AG | <strong>Tightening</strong> Technology 10 Working with the <strong>System</strong>10.1 Settings in the BS<strong>350</strong>Table 10–2: Quality codes and their meanings (section 2 of 2)Quality code Monitoring function NOK All other monitoring functions Category18 A+, T–, OK All20 A–, T–, OK All32 G+, OK All34 A+, G+, OK All36 A–, G+, OK All40 T+, G+, OK All42 A+, T+, G+, OK All44 A–, T+, G+, OK All48 T–, G+, OK All50 A+, T–, G+, OK All52 A–, T–, G+, OK All64 G–, OK All66 A+, G–, OK All68 A–, G–, OK All72 T+, G–, OK All74 A+, T+, G–, OK All76 A–, T+, G–, OK All80 T–, G–, OK All82 A+, T–, G–, OK All84 A–, T–, G–, OK All128 NOK OK/NOK <strong>System</strong>129 <strong>System</strong> error (fault) OK/NOK <strong>System</strong>130 Remove start signal ((C)Cw = 0) OK/NOK <strong>System</strong>130 Remove enable (En = 0) OK/NOK <strong>System</strong>131 Timeout sync/rework (t+ Sync/RW) OK/NOK <strong>System</strong>131 Timeout application (t+ app) OK/NOK <strong>System</strong>132 Synchronization (Sync) OK/NOK <strong>System</strong>133 Rework (RW) OK/NOK <strong>System</strong>136 NOK step (max. NOK)137 Redundancy torque (RedT) OK/NOK <strong>System</strong>138 Redundancy angle (RedA) OK/NOK <strong>System</strong>139 Start-up test (StartUp) OK/NOK <strong>System</strong>ExampleA+, T–, G+ means upper limit of angle, lower limit of torque and upper limit of gradient has been exceeded.Category of the tightening stepStandard tightening steps and extended tightening steps can be assigned to one of ten categories (seepage 212). A quality code can be linked to one or more categories when creating/changing the entriesin the quality code assignment table. A quality code is then only output if the tightening step that providedthe NOK result is also from the correct category.The entries in the standard quality code assignment table are either assigned to the <strong>System</strong> category(= intrasystem) or all categories (= All). New entries can only be explicitly assigned to the categories thatcan be set for a tightening step.Order of the entriesThe table is searched from top to bottom when selecting the quality code. The order of the entries is thusdecisive for the selection of the quality code.<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!