11.07.2015 Views

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

194/316 Bosch <strong>Rexroth</strong> AG | <strong>Tightening</strong> Technology 8 Basic Commissioning8.6 Operating the ErgoSpin hand-held nutrunnerTo start the tightening program to tighten the screw:1. In the program selection, select the program number, e.g. 1: Test tightening.2. Click on Start.3. Press the start button on the ErgoSpin within 15 s.To start the loosening program:⇒ Click on Loosen to start the loosening program (program 99, Ccw) independently of the programselection.Further functions– Stop stops the running program prematurely.– Reset acknowledges class 3 errors.– Standard indicates the number of times the selected tightening program can be started in a row.The system status displays are activated by selecting Start, Stop, or Loosen.The system status display to the left indicates the hardware's system status:– Green: <strong>Tightening</strong> channel is ready for operation– Red: <strong>System</strong> errorThe system status display to the right supplies information about the last tightening job:– Red: The last tightening result is NOK– Green: The last tightening result is OK– Gray: Invalid status, i.e. tightening channel is not ready for operation again or no tightening job hasbeen performed yetAfter a successful sequence test, both system status displays on the control panel and on the tighteningcontroller emit a static green light.8.5.7.2 Sequence test via the TFT display of the CS351E-GNote Follow the instructions in the “ErgoSpin” operating instructions, 3 609 929 965!The generated tightening programs can also be started via the TFT display (<strong>System</strong> test → Sequencetest). Here, the functions Loosen, Start, Stop, and Reset are identical to those in the BS<strong>350</strong>.Figure 8–19:Sequence test via the TFT display8.6 Operating the ErgoSpin hand-held nutrunnerThis section describes some of the special features for operating an ErgoSpin series hand-held nutrunner.<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!