142/316 Bosch <strong>Rexroth</strong> AG | <strong>Tightening</strong> Technology 7 Data Services7.4 Profibus DP communicationLayer 7Application layerInterface to the application program with application-orientedcommands (read, write).Layer 6Display layer, not defined.Layer 5Session layer, not defined.Layer 4Transport layer, not defined.Layer 3Network layer, not defined.Layer 2Backup layerDescription of the bus access process. Start and end charactersare added, the transfer could possibly be repeated if thereis a failure.Layer 1Bit transfer layerSets physical transfer of data bytes.Figure 7–38:OSI layer model for Profibus DP protocols7.4.1.2 Function diagramCS351PartnercontrollerInputsID codeControl signalsID codeEN CW CCW ABCDXXXX1 1 0 41 42 43 44 58 58 58 58OutputsResultsAngle Torque Control signals135.85° 101.100 Nm CyCmp OK NOKA4 BA 14 00 30 44 9A 00 1 1 0Figure 7–39:Functional diagram of data exchange via Profibus DP7.4.1.3 Exchanged dataThe following data can be exchanged via Profibus DP:– Control signals from/to the partner controller– ID code– <strong>Tightening</strong> results from single-channel tightenings<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008