11.07.2015 Views

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

7 Data Services <strong>Tightening</strong> Technology | Bosch <strong>Rexroth</strong> AG 91/3167.2 Ethernet communication7.2.3.3 Output formatsVarious formats are available for results output and you can select the format that is suitable for your application.The following output types are possible:– Standard Plus 310 (see page 101): This output format corresponds to the format “Standard Plus(docu step)” with the option “with preceding signs” from the <strong>Tightening</strong> <strong>System</strong> 310. Both the resultsfrom the last tightening step of a tightening sequence and the results from selected previous steps(so-called docu steps) 1) are output.Here, docu steps 1 to 9 are taken into account. Measurement values are output with positive or negativealgebraic signs.– Standard <strong>350</strong> (see page 97): Both the results from the last tightening step of a tightening sequenceand the results from the docu steps used in the tightening program are output.In addition to the Standard Plus 310 format, the incomplete docu steps are output along with theirset values.This output format also contains additional information such s the serial number of the hand-heldnutrunner or the target functions of a tightening step.7.2.3.4 Protocol elements of outputThe following protocol elements are used 2) :Parameters (alphabetical)ProtocolelementDescriptionStd Plus 310 Std <strong>350</strong>C (CR) * Carriage return (0x0D) X XRE (ETX) * End trigger character (0x03) X XXTL (LF) * Line feed (0x0A) X XFS O(SO) * Printer control character expanded print off (0x0E) X XS (STX) * Start trigger character (0x02) X XX T_ Space character X XA– Lower angle limit [°] (floating decimal) X XA* Angle result error [°] (floating decimal)A_ Angle result as a floating decimal number [°] X XA+ Upper angle limit [°] (floating decimal) X XA< Upper angle limit [°] (floating decimal) XAP Target function Angle XAR Differential redundancy angle as a floating decimal number [°] X XAR+ Upper limit for differential redundancy angle X XARS Threshold angle for AR X XAT Total angle (all steps from TAOS on) X XAT– Lower limit for total angle X XAT+ Upper limit for total angle X XCH Card rack/slot no., e.g. 2.2 X XD_ <strong>System</strong> date (e.g. 1999-03-30 acc. to ISO 8601) X X1) The setting that determines which step results will be contained in the results output is performedwhen the tightening program is created in the BS<strong>350</strong> operating system.2) In the illustration in this document, the controller characters (LF, CR …) are portrayed as symbols thatC Lhave the exact width of one letter (e.g.R,F). Thus, the character positions for the subsequent characterscorrespond in the illustration and file.<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!