LD 14<br />

Alphabetical list of prompts Page 221 of 1050<br />

Prompt Response Comment Pack/Rel<br />

TGAR (0)-15 Trunk Group Access Restriction: Release 1 to 13 basic-1<br />

(0)-31 Trunk Group Access Restriction: Release 13 to 21<br />

Where (0) removes existing restriction.<br />

0-(1)-31 Trunk Group Access Restriction<br />

The default of (1) automatically blocks direct access.<br />

TIMP Termination Impedance. Prompted if XTRK = XEM<br />

or XUT.<br />

(600) 600 ohms<br />

900 900 ohms<br />

1200 1200 ohms<br />

Use 1200 ohms for RAN trunks and (600) or 900 for all<br />

others.<br />

When using the Enhanced Universal Trunk card with<br />

Release 19, only 600 or 900 ¾ terminating impedance is<br />

allowed. However, more Terminating and Balance<br />

impedance (BIMP) <strong>com</strong>binations are available.<br />

The terminating and balance impedance options are:<br />

TIMP BIMP<br />

600 600<br />

600 3COM<br />

900 3COM<br />

900 900<br />

900 3CM2<br />

600 3CM2<br />

For XUT trunks, the Termination Impedance or TIMP must<br />

be <strong>com</strong>patible with the Balance Impedance or BIMP.<br />

The following <strong>com</strong>bination of BIMP/TIMP are allowed:<br />

Timp Impedance Bimp Impedance<br />

600 ohms 3-<strong>com</strong>ponent or 3<strong>com</strong><br />

900 ohms 3-<strong>com</strong>ponent or 3<strong>com</strong><br />

600 ohms 600 ohms<br />

1200 ohms 600 ohms<br />

For XEM trunks, TIMP must be set to 600.<br />

When CLS = JDID, TIMP must be set to 600.<br />

tip/xpe-19<br />

TKID nnnnnnn Trunk Identifier basic-6<br />

Does not have to be unique. Default is no trunk identifier<br />

assigned.<br />