LD 17<br />

Page 502 of 1050 Alphabetical list of prompts<br />

Prompt Response Comment Pack/Rel<br />

SSUP (NO) YES Senior Supervisor acdc-1<br />

Device assigned used by senior supervisor/load<br />

manager. Cannot be YES if prompt APRT is YES.<br />

STOP (1)-1X5-2 Number of stop bits<br />

To enter 1.5, use 1X5. (Options 51C, 61C, 81 and<br />

81C do not support 1.5). Prompted for asynchronous<br />

ESDI ports.<br />

For Option 11C, STOP is not prompted for<br />

CARD 0 PORT 0 or when TTY_TYPE = PTY.<br />

553-3001-311 Standard 6.00 June 1999<br />

cls-19<br />

SUPPRESS alarm-19<br />

0-(5)-127 Alarm occurrence threshold (prior to suppressing)<br />

This determines the number of times an alarm may<br />

occur before it is no longer output. Entering 0<br />

indicates that all alarm occurrences are output<br />

(no suppression)<br />

SYNC (NO) Asynchronous mode of operation for ESDI port csl-7<br />

YES Synchronous mode of operation for ESDI port<br />

SYNM Synchronization Mode ida-16<br />

(0) No synchronization<br />

1 Main input from Digital Trunk Signaling Link or DTSL<br />

2 Main input and standby input from DTSL<br />

3 Main input from external clock<br />

4 Main input from DTSL; standby input from external<br />

clock<br />

5 Main input from external clock; standby input from<br />

DTSL<br />

SYNM is prompted with Integrated Digital Access<br />

(IDA) package 122.<br />

T1 2-(4)-20 Retransmission Timer cls-7<br />

Range in units of 0.5 seconds, (4) = two seconds<br />

T2 0-(10)-255 Maximum Time allowed without a frame being<br />

exchanged.<br />

cls-7<br />

T200 2-(3)-40 Retransmission Timer pri-12<br />

Entry is in units of 0.5 seconds.