LD 17<br />

Alphabetical list of prompts Page 495 of 1050<br />

Prompt Response Comment Pack/Rel<br />

Connected Number IE Presentation is supported on<br />

Indonesian interfaces.<br />

Default value for ESIG, ISIG, NI2, EUROISDN and<br />

Indonesian interfaces except AUS, EIR, DUT, BEL,<br />

FRA interfaces.<br />

XCOL to remove Connected Number IE Presentation<br />

Default value for all APAC, AUS, EIR, DUT, BEL and<br />

FRA interfaces.<br />

CTI Call Transfer Integer<br />

CTI and CTO are mutually exclusive.<br />

CTO Call Transfer Object<br />

DV1I<br />

DV1O<br />

DV2I<br />

DV2O<br />

DV3I<br />

DV3O<br />

MCID<br />

XMCI<br />

CTI and CTO are mutually exclusive.<br />

QSIG SS Call Diversion Notification remote<br />

capability. Configure sending of QSIG Diversion<br />

Notification Information, treatment of Rerouting<br />

request and coding of operations. If coded as Object<br />

Identifier, the remote capability ends with ‘O”,<br />

whereas for Integer Value, the remote capability<br />

ends with ‘I’. Only one remote capability is allowed.<br />

Diversion information is sent to remote switch.<br />

Diversion information is sent to remote switch.<br />

Rerouting requests from remote switch are<br />

processed.<br />

Rerouting requests from remote switch are<br />

processed.<br />

Diversion information is sent to remote switch.<br />

Rerouting requests from remote switch are<br />

processed.<br />

Diversion information is sent to remote switch.<br />

Rerouting requests from remote switch are<br />

processed.<br />

Precede with ‘X’ to remove capability.<br />

MCID = Add MCID as a new remote capability.<br />

To remove remote capability.<br />

basic- 23<br />

qsig ss-24<br />

qsig ss-24<br />

qsig ss- 23<br />

etsi-ss- 23<br />

MQC MCDN QSIG Conversion as a Remote capability meet-24<br />

MSL Remote D-channel is on a MSDL card<br />

MWI Message Waiting Interworking with DMS-100<br />

(Release 19)<br />