LD 17<br />

Page 500 of 1050 Alphabetical list of prompts<br />

Prompt Response Comment Pack/Rel<br />

SECU (NO) YES Security for Meridian Link applications<br />

When set to NO, the host <strong>com</strong>puter must specify<br />

both the TN and DN of the associate set in connect,<br />

answer and release messages.<br />

Prompted when the Integrated Services Digital<br />

Network Application Module Link for Third Party<br />

Vendors (IAP3P) package 153 is equipped for<br />

ISDN/AP Third Party.<br />

SEMT (1)-5 Number of Status Enquiry Messages sent within 128<br />

ms from the network side<br />

553-3001-311 Standard 6.00 June 1999<br />

iap3p-12<br />

msdl-24<br />

SEVERITY Alarm Severity of a particular alarm entry alarm-19<br />

(NONE) No rating (default status)<br />

CRITICAL System operation is in jeopardy<br />

MAJOR Serious condition, the system is operational<br />

MINOR Error condition detected, system operation not<br />

affected<br />

Retains current value<br />

SID xxxx System ID number basic-1<br />

The SID is used for polling an SL-1 for ACD, CDR<br />

and traffic reports. It can also be printed and<br />

changed using LD 2.<br />

SIDE Meridian 1 node type pri-12<br />

(USR) Slave to the controller<br />

NET Network, the controlling switch<br />

Prompted only if IFC = SL-1, ESIG or ISIG. Opposite<br />

sides of the PBX-to-PBX interface must be set as<br />

NET or USR. The call processing software uses<br />

these labels to handle call collision.<br />

SIZE (0)- 65534 Size of History File buffer in characters<br />

The History File stores system messages in<br />

Protected Data or P data and uses an SDI port<br />

address. The History File survives initialization, but<br />

is lost when SYSLOAD occurs or the length of the<br />

file is changed.<br />

The History File cannot be created if all 16 I/O ports<br />

are defined. Prompted if ADAN = HIST or TRF<br />

hist-18