LD 15<br />

Alphabetical list of prompts Page 295 of 1050<br />

Prompt Response Comment Pack/Rel<br />

ICPS ICP Printer Search icp-10<br />

(CIR) Circular search<br />

COM Common printer for all consoles<br />

Type of Intercept Computer printer search, done when<br />

more than one console is used.<br />

ICTD (NO) YES Intercept Computer Terminal Dial from directory<br />

This prompt allows an intercept position of attendant<br />

type to dial an extension DN from the Intercept<br />

Computer Terminal.<br />

icp-10<br />

ICWN (0)-511 Intercept Computer Owner tens-9<br />

Prompted with Multi-Tenant Service (TENS) package<br />

86. Tenant that owns the intercept <strong>com</strong>puter.<br />

IDBZ (NO) YES Enable Individual Attendant DN Buzzing. basic- 23<br />

IDCA (NO) YES In<strong>com</strong>ing DID Digit Conversion Allowed idc-12<br />

NFCR must = YES before IDCA can = YES.<br />

Prompted with In<strong>com</strong>ing Digit Conversion (IDC)<br />

package 113<br />

IDEF Internal/external definition<br />

Network wide INY/EXT definition for Call Forward/Hunt<br />

by Call Type, Internal Call Forward, and Break In<br />

Indication Prevention.<br />

(NO) A call will not be treated as internal or external<br />

according to the network wide definition of internal and<br />

external calls. When IDEF = NO, information that could<br />

have been entered previously at the IDEF prompt in LD<br />

16 will not influence call treatment.<br />

YES A call will be treated as internal or external according to<br />

the network wide definition of internal and external calls.<br />

Changing IDEF to NO and then back to YES will not<br />

reset the data entered in LD 16.<br />

basic-22<br />

IDR 0-511 Identification Error RAN number supp-16<br />

X To disable the RAN<br />

IFLS (NO) Allow switchhook flash signal from 500/2500 sets mpo-20<br />

YES Ignore switchhook flash signal from 500/2500 sets<br />

If YES then sets require ground buttons.<br />