702<br />

LD 27<br />

LD 27: ISDN Basic Rate Interface (BRI)<br />

<strong>Administration</strong><br />

LD 27<br />

Issued: June 1999<br />

Status: Standard<br />

<strong>X11</strong> Release: 24<br />

Page 671 of 1050<br />

Overlay program 27 was introduced in Release 18 and is used to configure<br />

ISDN Basic Rate Interface hardware.<br />

If ISDN BRI is being configured for the first time the following sequence<br />

must be used:<br />

1 Configure Protocol group (PROT) data block (Release 18), Link Access<br />

Protocol on D-channel (LAPD) data block (Release 19 and later).<br />

2 Configure PRI loop, route, and channel data blocks for packet data<br />

transmission (Release 18).<br />

3 Configure Multi-purpose ISDN Signaling Processor (MISP) data block.<br />

4 Configure Basic Rate Signaling Concentrator (Release 19 and later).<br />

5 Configure S/T Interface Line Card (SILC) or U Interface Line Card<br />

(UILC) data block.<br />

6 Configure Digital Subscriber Loop (DSL) data block.<br />

7 Configure Terminal Service Profile on DSL (TSP) data block.<br />

If changing the existing ISDN BRI service this sequence does not have to be<br />

followed, but the relationship of one data block to another must be observed.<br />

Due to interactions the changing of one data block may require the changing<br />

of other data blocks.<br />

Refer to the ISDN BRI <strong>Administration</strong> NTP for <strong>com</strong>plete details.<br />

<strong>X11</strong> <strong>Administration</strong>