LD 15<br />

Page 278 of 1050 Alphabetical list of prompts<br />

Prompt Response Comment Pack/Rel<br />

CWBZ Call Waiting Buzz basic-1<br />

(NO) YES First field-Provide two second buzz on exceeding upper<br />

CWCL or CWTM threshold.<br />

(NO) YES Second field-Buzz on first call entering queue.<br />

CWCL Call Waiting Call Limit<br />

(0)-255 (0)-255<br />

Lower and upper thresholds.<br />

The Call Waiting lamp starts flashing when number of<br />

calls in the queue exceeds the upper threshold. The<br />

lamp continues to flash until the number of calls in<br />

queue is less than the lower threshold. Enter 0 to<br />

disable this feature.<br />

basic-1<br />

(0)-1000 (0)-1000<br />

Lower and upper thresholds defined as a percentage of<br />

the active consoles when OPT = FACA.<br />

553-3001-311 Standard 6.00 June 1999<br />

When the FACA/FACD option is changed, a new value<br />

for CWCL must be set or the default values are used.<br />

The CWCL values for the tenant-level are set equal to<br />

the customer-level values. CWCL is also prompted in<br />

LD 93.<br />

CWTM (0)-511 (0)-511<br />

Lower and upper thresholds for Call Waiting Time.<br />

The Call Waiting lamp starts flashing when the call in<br />

the queue exceeds the upper threshold. The lamp<br />

continues to flash until the wait time is less than the<br />

lower threshold. Enter 0 to disable this feature.<br />

basic-1<br />

CWUP (NO) YES Call Waiting queue Update dcon-15<br />

Prompted with M2250 Attendant Console (DCON)<br />

package 140. The M2250 type consoles can be notified<br />

every time there is a change to the Call Waiting queue.<br />

DACT_BUSY Boss’s Lamp status when BSFE is disabled and set is<br />

busy.<br />

(LIT) LCD Lamp is on.<br />

WINK LCD Lamp flash rate is 60 impulses per minute.<br />

FLSH LCD Lamp flash rate is 30 impulses per minute.<br />

DARK LCD Lamp is off.<br />