4.1.6 Terminal wiring diagram (POWER terminal block)<br />

1) Wiring of <strong>Inverter</strong> below 7.5kW<br />

External<br />

Fuse<br />

2) Wiring of 11~22kW Product<br />

R(L1) S(L2) T(L3) P(+) B N(-) U V W<br />

3) Wiring of 30~75kW Product<br />

R(L1) S(L2) T(L3) P1(+) P2(+) N(-) U V W<br />

4) Wiring of 90~160kW Product<br />

Note<br />

Ground terminal<br />

R(L1) S(L2)<br />

3Phase<br />

3Phase<br />

AC<br />

AC<br />

3-phase AC input<br />

power supply<br />

T(L3)<br />

P(+) B<br />

Dynamic brake resistor<br />

N(-) U V W<br />

R(L1) S(L2) T(L3) P(+) N(-) U V W<br />

Chapter 4 Wiring<br />

Products over 11kW have a linear arrangement of terminal blocks. Products for 0.75~160kW have built-in DC<br />

Reactor, so it does’t necessary any other DC Reactor connection. Ground terminal must be grounded. Do not<br />

use ground to command for ground cable, welding machine and power machine etc. Ground cable must be<br />

IM<br />

IM<br />

wire as short as possible. If ground terminal of inverter is far from the inverter,electric potential of inverter<br />

terminal ground can be unstable because leakage current of inverter can be gernerated form inverter.<br />

Motor<br />

4-7