14. Clock Estimation<br />

14.3 Clock RINEX Utility in <strong>Bernese</strong> <strong>GPS</strong> <strong>Software</strong> (CCRNXC)<br />

Four programs in the <strong>Bernese</strong> <strong>GPS</strong> <strong>Software</strong>, <strong>Version</strong> <strong>5.0</strong> , write clock RINEX files:<br />

CODSPP may store the used satellite clock corrections together with the estimated station<br />

clocks into a clock RINEX file (see Section 6.3).<br />

<strong>GPS</strong>EST may save the results of the epoch-wise satellite/station clock estimation into a<br />

clock RINEX file (see Section 14.2).<br />

CLKEST may be used for efficiently compute high-rate clocks (see Section 14.5).<br />

CCRNXC manipulates clock RINEX files and may write the results into a clock RINEX file<br />

again.<br />

In <strong>Version</strong> <strong>5.0</strong> the clock RINEX format is used also as internal clock format of the <strong>Bernese</strong><br />

<strong>GPS</strong> <strong>Software</strong> if satellite and station clocks have to be stored together.<br />

Only the program CCRNXC (”Menu>RINEX>RINEX utilities>Combine/manipulate clock data”) is able to<br />

read clock RINEX files. It is the clock RINEX utility of the <strong>Bernese</strong> <strong>GPS</strong> <strong>Software</strong> and<br />

may be used to<br />

• import clock RINEX files from external sources to extract the satellite clock information<br />

into a <strong>Bernese</strong> satellite clock file,<br />

• cut/concatenate clock RINEX files as well as to extract selected clocks from input<br />

files,<br />

• merge or combine clock RINEX files,<br />

• compare clock RINEX files,<br />

• select a reference clock and align the clock values to this reference,<br />

• detect jumps in the clock time series, and<br />

• extrapolate clock time series.<br />

The program provides a lot of options. They are explained in the following sections for some<br />

standard applications.<br />

14.3.1 Extracting Satellite Clocks from Clock RINEX Files<br />

The extraction of satellite clock corrections from an input clock RINEX file and writing of<br />

a corresponding <strong>Bernese</strong> satellite clock file is very simple. Mark the checkbox “Extract only<br />

satellite clocks” in panel “CCRNXC 1: Filenames”. The satellite clock values from each input<br />

clock RINEX file are copied without any modifications into a <strong>Bernese</strong> satellite clock file<br />

with the same name as the input file but in a different directory. By default clock RINEX<br />

files are located in the campaigns OUT-directory while <strong>Bernese</strong> clock files are located in the<br />

ORB-directory.<br />

Page 298 AIUB