SafetyLon 47-13<br />

Acronyms<br />

1oo2<br />

COTS<br />

CRC<br />

LNS<br />

LON<br />

LSWord<br />

MSWord<br />

SADR<br />

SFF<br />

SIL<br />

SLA<br />

SLL<br />

DU<br />

DD<br />

SD<br />

SU<br />

One out of two<br />

Commercial off the shelf<br />

Cyclic redundancy check<br />

Local network service<br />

Local operating network<br />

Leas significant word<br />

Most significant word<br />

Safe address<br />

Safe failure fraction<br />

Safety integrity level<br />

SafetyLon application<br />

SafetyLon library<br />

Dangerous undetected<br />

Dangerous detected<br />

Safe detected<br />

Safe undetected<br />

References<br />

1. International Electrotechnical Commission. IEC 61508—Functional safety of electric/electronic/<br />

programmable electronic safety-related <strong>systems</strong>. IEC, Geneva, Switzerland, 1998.<br />

2. European Norm. EN 14908—Open data <strong>communication</strong> in building automation, controls and<br />

building management—control network protocol. CEN, 2005.<br />

3. T. Novak, P. Fischer, M. Holz, M. Kieviet, and T. Tamandl. Safe commissioning and maintenance<br />

process for a safe system. In Proceedings of the Seventh IEEE International Workshop on Factory<br />

Communication Systems, Dresden, Germany, pp. 225–232, 2008.<br />

4. Institute of Electrical and Electronics Engineers Computer Society. IEEE Standard for Software<br />

Safety Plans. IEEE Std. 1228, 1994.<br />

5. C. Hatton. Safer C—Developing Software for High-Integrity and Safety-Critical Systems. McGraw-Hill<br />

Book Company Europe, Berkshire, U.K., 1995.<br />

6. T. Novak and T. Tamandl. Architecture of a safe node for a fieldbus system. In Proceedings<br />

of the Fifth IEEE International Conference on Industrial Informatics, Vol. 1, Vienna, Austria,<br />

pp. 101–106, 2007.<br />

7. International Electrotechnical Commission. IEC 61508—Functional safety of electric/electronic/<br />

programmable electronic safety-related <strong>systems</strong>—Part 2: Requirements for electrical/electronic/programmable<br />

electronic safety-related <strong>systems</strong>. IEC, Geneva, Switzerland, 2000.<br />

8. T. Tamandl and P. Preininger. Online self tests for microcontrollers in safety related <strong>systems</strong>. In<br />

Proceedings of the Fifth IEEE International Conference on Industrial Informatics, Vol. 1, Vienna,<br />

Austria, pp. 137–142, 2007.<br />

9. P. Wratil and M. Kieviet. Sicherheitstechnik für Komponenten und Systeme. Hüthig Verlag, Heidelberg,<br />

Germany, p. 203, 2007.<br />

10. H. Hölscher and J. Rader. Microcomputers in Safety Technique, an Aid to Orientation for Developer<br />

and Manufacturer. TÜV Rheinland, Cologne, Germany, p. 50, 1986, Chapter 7.<br />

11. H. Hölscher, J. Rader. Microcomputers in Safety Technique, an Aid to Orientation for Developer and<br />

Manufacturer. TÜV Rheinland, Cologne, Germany, p. 86, 1986, Chapter 7.<br />

12. T. Novak and B. Sevcik. Network time synchronization in a safe automation network. In Proceedings<br />

of the Seventh IEEE International Workshop on Factory Communication Systems, Dresden, Germany,<br />

pp. 305–313, 2008.<br />

© <strong>2011</strong> by Taylor and Francis Group, LLC