6 The Traffic Network<br />

6.7.2.2 Properties & Options<br />

[LOCATION]<br />

● No.: The physical channel<br />

number that the signal control<br />

program uses. Multiple<br />

detectors of the same<br />

controller can have the same<br />

channel number, causing the<br />

controller to treat them as one<br />

detector. This allows <strong>VISSIM</strong><br />

to model detectors reaching<br />

over multiple lanes by defining<br />

one detector per lane coded<br />

with the same number.<br />

● Name: Label or comment.<br />

● SC (signal controller):<br />

Associates the detector to the<br />

controller.<br />

● Length defines the length of the detector. A value of 0 is permitted (e.g.<br />

for push buttons). The detector is then displayed as a thin line.<br />

● Type: Choose the appropriate detector type:<br />

- Standard detectors register PT vehicles like any detector.<br />

- Pulse detectors do not pass any presence/occupancy information to<br />

the signal controller.<br />

- Presence detectors do not pass any pulse information (vehicle front<br />

ends or rear ends) to the signal controller.<br />

- Public transport calling points only detect PT vehicles that send out<br />

PT telegrams, cf. section 6.5.2 for details.<br />

● At contains the detector’s link coordinate.<br />

● Lane: Defines the lane number where the detector is placed.<br />

● Before stop: The detector’s distance to the next signal stop line (available<br />

only if the stop line is located on the same link).<br />