24.08.2013 Views

VISSIM 5.30-05 User Manual

VISSIM 5.30-05 User Manual

VISSIM 5.30-05 User Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Test of Signal Control without Traffic Simulation<br />

8.2 Test of Signal Control without Traffic Simulation<br />

<strong>VISSIM</strong> offers the Test function to analyze a signal control logic’s behavior<br />

with various detector call scenarios without actually modeling traffic flows.<br />

Detector calls are generated through<br />

► interactive mouse clicks or<br />

► pre-recorded macros.<br />

The Test function is helpful when debugging a newly developed control logic<br />

especially if it contains only sporadically used functions such as railroad<br />

preemption, PT signal priority or queue “flush-out”. <strong>VISSIM</strong> discriminates<br />

between the following detector actuations:<br />

Single<br />

Actuation<br />

Repeated<br />

Actuation<br />

Continuous<br />

Actuation<br />

Increasing impulse (vehicle front) and decreasing impulse<br />

(vehicle end) within one second<br />

Increasing and decreasing impulse during every second;<br />

equivalent to a single actuation each second<br />

Single impulse increase; impulse decrease only after explicit<br />

termination of actuation<br />

8.2.1 Interactive Placement of Detector Calls<br />

To place detector calls (actuations) follow the steps outlined below:<br />

1. In VIEW - OPTIONS - [TRAFFIC], activate Individual Vehicles.<br />

2. In VIEW - NETWORK ELEMENTS activate the display of Detectors.<br />

3. If you would like to create a Signal/Detector protocol (cf. section 11.9),<br />

toggle the appropriate options in EVALUATIONS – FILES and/or – WINDOWS.<br />

4. If the sequence of detector actuations is to be stored for later testing of<br />

other control strategies, activate the macro functionality using TEST –<br />

RECORDING.<br />

5. Start the test function with TEST – CONTINUOUS or TEST – SINGLE STEP.<br />

Starts the continuous Test run. F5<br />

Calls the next step in the Single step mode;<br />

Allows also toggling from Continuous to Single Step<br />

mode during the Test run.<br />

6. Activate individual detector calls by clicking:<br />

- Left mouse button: In Single Step mode, switch from no actuation<br />

(black) to single actuation (blue) and to repeated actuation (cyan)<br />

and back to no actuation.<br />

- Right mouse button: Place (as well as terminate) a continuous<br />

actuation (purple).<br />

<strong>User</strong> <strong>Manual</strong> © PTV AG 2011 457<br />

F6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!