Signal Controllers<br />

Double-click a stage or click Remove stage in the context menu to remove<br />

the selected stage from the sequence.<br />

CLEAR SEQUENCE in the context menu will delete the stage sequence<br />

completely.<br />

The context menu command EXPORT… allows for stage sequence export as<br />

an image file. Set the format options for the image file via menu EDIT -<br />

OPTIONS in the [EXPORT] tab, cf. section 6.7.4.10.<br />

To create a signal program with fixed cycle times from the stage sequences,<br />

the following options are provided:<br />

● Cycle time tu: Enter the duration in seconds.<br />

● CREATE STAGE BASED SIGNAL PROGRAM: Click this button to calculate a<br />

stage-based signal program for a predefined cycle time. The Signal<br />

programs editing view appears and allows for further signal program<br />

editing, cf. section 6.7.4.6.<br />

● CREATE SIGNAL GROUP BASED SIGNAL PROGRAM: Click this button to<br />

calculate a signal group-based signal program for a predefined cycle<br />

time. The Signal programs editing view appears and allows for further<br />

signal program editing, cf. section 6.7.4.6.<br />

You may manually define the interstages to be used for signal program<br />

calculation. Right-click the dark-gray space between the two desired stages<br />

and click INTERSTAGES - CREATE… in the context menu or select an existing<br />

interstage.<br />

These steps are performed if the interstages were not manually selected:<br />

For each stage changeover in the sequence of stages it is checked whether<br />

there is already an appropriate interstage. If so, the first matching interstage<br />

is used for the calculation, otherwise a new interstage will be created. The<br />

new interstage will be stored for stage-based signal programs, whereas it will<br />

be deleted after signal program calculation in case of signal group-based<br />

signal programs.<br />

<strong>User</strong> <strong>Manual</strong> © PTV AG 2011 315