6 The Traffic Network<br />

they will still work though the data folder might have been renamed or<br />

copied.<br />

For a signal control of the External type, the number of the signal program<br />

can also be entered while the simulation is running. <strong>VISSIM</strong> automatically<br />

switches to the new signal program at the next switch point.<br />

With external controller DLLs, the current cycle second (determined by<br />

<strong>VISSIM</strong> for fixed cycle times) is computed on the basis of the start of the<br />

first cycle at midnight. If 00:00:00 is set as start time, this will not make a<br />

diference.<br />

6.7.3.10 Fixed time control<br />

The external SC type Fixed time control is a fixed time control strategy. The<br />

Signal Control Editor replaces the original tabular data supply method for<br />

fixed time controls. The graphical signal program editor allows for changes to<br />

the signal timing plan. Due to the particular <strong>VISSIM</strong> license, the signal<br />

program editor’s add-on VISSIG provides additional functionality beyond the<br />

<strong>VISSIM</strong> standard version.<br />

For Fixed time control, significant changes have been performed and the<br />

functionality has been extended by various new features, by the VISSIG<br />

add-on, for example. Please refer to section 6.7.4 for the comprehensive<br />

description.<br />

For stage-based fixed time controllers, the greentime optimization can be<br />

performed, cf. section 6.7.3.11:<br />

► For the selected fixed time controller via the button START OPTIMIZATION<br />

in the Signal control window – [FIXED TIME] tab.<br />

► For all fixed time based controllers in the network via menu SIGNAL<br />

CONTROL - OPTIMIZATION OF ALL FIXED TIME CONTROLLERS.<br />

Definition<br />

Via SIGNAL CONTROL – EDIT CONTROLLERS... open the Signal Control window<br />

and create a signal control with fixed time control.<br />

By right-click in the list you can call a context menu. The context menu<br />

provides the following functions:<br />

► NEW adds another SC to the list<br />

► DUPLICATE creates a new SC with the properties of the selected one but a<br />

new SC no.<br />

► DELETE removes the selected entry from the list<br />