6 The Traffic Network<br />

To the new signal groups, the signal state sequence Red-Red / Amber-<br />

Green-Amber is assigned. To ease data input the following is<br />

recommended: Create a signal group for each of the required signal group<br />

types, supply their standard signal sequence and duplicate this template<br />

finally as often as necessary.<br />

Furthermore, you may edit the list as follows:<br />

● No.: Double-click in the column and edit the number of the signal group.<br />

● Name: Double-click in the column and edit the name of the signal group.<br />

● Notes: Double-click in the column to call the editing view. You may enter<br />

a comment describing the signal group.<br />

The editing view<br />

Here you may change the parameters of the particular signal group as<br />

follows:<br />

● Name: Short “speaking” name of the signal group.<br />

● Default sequence: Except for permanent signal sequences, any signal<br />

state sequence mentioned in section ● can be selected:<br />

- Red – Red / Amber – Green - Amber<br />

- Red - Green<br />

- Red – Red / Amber – Green - Flashing Green - Amber<br />

- Red – Green - Flashing Green<br />

- Red – Green - Amber<br />

If option Add minimum times in interstage has been checked via menu<br />

VIEW - Options - [OPTIMIZATIONS], increasing the duration of either the<br />

minimum green or increasing the duration of a fixed state may force the<br />

recalculation of particular interstages. Prior to storing the new data it is<br />

checked which of the interstages have to be recalculated. The appropriate<br />

query appears, if applicable.<br />

Also changes to current optimization settings or to stages may lead to<br />

recalculations which are not caused by the changes themselves.<br />

● Default durations: Graphical display of the signal state sequence. The<br />

particular value of the signal state is shown. Double-click for value<br />

modification.<br />

● Notes: Enter a comment describing the intended usage of the signal<br />

group.<br />