[SIGTIMTBL.<br />

CFG]<br />

[SC/DET.<br />

REC]<br />

Signal Controllers<br />

● Offset: A value that delays the first (and therefore all subsequent) cycle<br />

by seconds.<br />

For Fixed time control, significant changes have been performed and the<br />

functionality has been extended by various new features, One of them is<br />

the VISSIG add-on, for example. Please refer to section 6.7.3.10 for the<br />

comprehensive description.<br />

For the selected control strategy, the tabs contain special data, e.g. input file<br />

names etc. (see below).<br />

Here, the settings for the Signal timing plan display window (during<br />

simulation run) can be edited, cf. section 11.8.<br />

For SC using an external control strategy, the SC/Detector Record settings<br />

can be edited, cf. section 11.9.<br />

6.7.3.3 VAP - Vehicle-Actuated Signal Control (optional module)<br />

<strong>VISSIM</strong> can model actuated signal control in conjunction with an external<br />

signal state generator if the optional VAP module is installed. This signal<br />

state generator allows users to define their own signal control logic including<br />

any type of special features (e.g. PT priority, railroad preemption, emergency<br />

vehicle preemption, variable message signs on motorways etc.). The use of<br />

the external signal state generator and its VAP programming language is<br />

explained in file VAP.PDF in the DOCUMENTS folder of your <strong>VISSIM</strong><br />

installation. VisVAP (the optional graphical desktop to model flow chart<br />

logics) is explained in file VISVAP.PDF in the DOCUMENTS folder of your<br />

<strong>VISSIM</strong> installation.<br />

<strong>User</strong>s of the 32 bit edition of <strong>VISSIM</strong> receive the 32 bit version of the VAP<br />

DLL files. Accordingly, the 64 bit version of the VAP DLLs is provided for<br />

users of the 64 bit edition of <strong>VISSIM</strong>.<br />

For VAP signal controllers using an Offset, values within VAP need to be<br />

adapted by this offset, too, in order to prevent malfunction of the time<br />

conditions.<br />

6.7.3.4 SCATS (optional module)<br />

SCATS requires<br />

► the files SCATS.DLL and SCATS_GUI.DLL and<br />

► the progams WinTraff and ScatSim (and SimHub if applicable).<br />

These are provided by the Roads and Traffic Authority of New South Wales,<br />

Australia.<br />

<strong>User</strong> <strong>Manual</strong> © PTV AG 2011 291