11 Evaluation Types for Simulations of Vehicles<br />

11.9 Signal Control / Detector Record<br />

Title<br />

per column<br />

The SC/Detector record is user-definable record of signal status, detector<br />

actuations and internal parameters and variables for every signal controller<br />

with external control logic. This record can be generated for simulation as<br />

well as for test runs and provides a platform to contain all important<br />

parameters and variable values. The SC/Detector record can be displayed in<br />

a window on the desktop and/or stored in an output data file (*.LDP).<br />

For output to file, please click menu EVALUATION – FILES - [SIGNAL CONTROL] tab<br />

and check option Signal Control / Detector Record.<br />

Definition<br />

No additional definition required.<br />

Configuration<br />

To create or edit a configuration of the SC/Detector Record follow the steps<br />

outlined below:<br />

1. Select SIGNAL CONTROL - EDIT CONTROLLERS...<br />

2. Select the controller to be edited from the list of all coded SC.<br />

3. In the [LDP CONFIG] tab page, data can be edited.<br />

In the Layout of columns list, a user-definable Title can be specified for the<br />

selected entry, which will be used instead of the preset <strong>VISSIM</strong> column<br />

header in the record file.<br />

Short title: Tick this option to save space within the header (especially for<br />

window output). Then for default headers abbreviated column headers are<br />

used.<br />

528 <strong>VISSIM</strong> <strong>5.30</strong>-<strong>05</strong> © PTV AG 2011