11 Evaluation Types for Simulations of Vehicles<br />

11.20 Special Evaluations (Discharge rate evaluation)<br />

The option Special Evaluations contained in the Offline Analysis (File)<br />

window (EVALUATION – FILES… - [VEHICLES]) enables any evaluations that have<br />

to be entered within the input file directly.<br />

In this section the evaluation of the discharge rate (which is the reciprocal of<br />

the saturation flow) is explained.<br />

A discharge in most cases will be measured at a stop line of a signal control.<br />

In order to get reasonable values for the discharge rate the flows that are<br />

measured need to be saturated (i.e. at least as many vehicles queuing as<br />

can pass at green time).<br />

Definition<br />

For every discharge rate evaluation, a signal head and a data collection point<br />

at the position of the signal head needs to be defined.<br />

The discharge rate evaluation is then defined directly in the *.INP file (using a<br />

text editor) like this:<br />

EVALUATION TYPE DISCHARGE SCJ 1 SIGNAL_GROUP 2 COLLECTION_POINT 1<br />

TIME FROM 0.0 UNTIL 99999.0<br />

In this example, the evaluation refers to the green times of signal group 2 of<br />

SC 1, and the times are measured at data collection point 1 which needs to<br />

be located at the corresponding stop line. The time interval is usually set to a<br />

value at least as large as the simulation period.<br />

Configuration<br />

No additional configuration required.<br />

Results<br />

The result for each discharge rate evaluation will be written to a separate file<br />

(wit h ascending extensions starting with *.A00, then *.A01, *.A02, etc.).<br />

A Discharge rate evaluation file (*.A**) contains the following information:<br />

► File title<br />

► Path and name of the input file (File)<br />

► Simulation comment (Comment)<br />

► Date and time of the evaluation (Date)<br />

► Version no. with Service pack no. and Build no. (<strong>VISSIM</strong>)<br />

► Details, e.g. Discharge at SC 10, signal group 4 (data collection point 10422)<br />

► Data block:<br />

- Each line refers to one green time (one cycle).<br />

- The 1 st first column contains the simulation time of the start of the<br />

green time.<br />

558 <strong>VISSIM</strong> <strong>5.30</strong>-<strong>05</strong> © PTV AG 2011