Special Evaluations (Discharge rate evaluation)<br />

- The 2 nd column is the elapsed time between the start of the green<br />

time and the arrival of the first vehicle at the data collection point.<br />

- The 3 rd column is the time gap between both the front ends of vehicle<br />

#1 (vehicle at 1 st position in the queue) and vehicle #2. Thus it is the<br />

time vehicle #2 needs to clear its queue position which is the<br />

Discharge Rate of vehicle #2.<br />

- The following columns contain all subsequent Discharge Rates<br />

according to the vehicle positions.<br />

- Numbers in parenthesis show the number of vehicles passed during<br />

that green time and their average Discharge Rate (both not including<br />

the Discharge Rate of vehicle #1 because that time depends on the<br />

location of the data collection point).<br />

- Values after parenthesis are the Discharge Rates of vehicles<br />

crossing the stop line after the green time (during amber or even<br />

red).<br />

- The 4 th line from the bottom contains the index of the vehicle’s<br />

position in the queue for each signal cycle.<br />

- The 3 rd line from the bottom contains the average Discharge Rates<br />

for the corresponding vehicle position.<br />

- The 2 nd line from the bottom contains the number of all vehicles<br />

measured for that position (higher indices might have smaller<br />

numbers if the flow is not saturated at all times).<br />

- The bottom line shows the total number of vehicles and total<br />

Discharge Rate for the whole evaluation period.<br />

Example (*.A00 file)<br />

Discharge Rate Evaluation<br />

File: e:\programfiles\vissim520\example\manual.inp<br />

Comment: <strong>Manual</strong> example<br />

Date: T Wednesday, May 2, 2009, 15:43:02<br />

<strong>VISSIM</strong>: 5.20-00 [19061]<br />

Discharge at SC 10, signal group 4 (data collection point 10422)<br />

<strong>User</strong> <strong>Manual</strong> © PTV AG 2011 559