11 Evaluation Types for Simulations of Vehicles<br />

11.4 Queue Counters and Vehicle Stops<br />

The queue counter feature in <strong>VISSIM</strong> provides as output the<br />

► average queue length,<br />

► maximum queue length and<br />

► number of vehicle stops within the queue.<br />

Queues are counted from the location of the queue counter on the link or<br />

connector upstream to the final vehicle that is in queue condition. If the<br />

queue backs up onto multiple different approaches the queue counter will<br />

record information for all of them and report the longest as the maximum<br />

queue length.<br />

The back of the queue is monitored until there is not a single vehicle left over<br />

on the approach that still meets the queue condition, though other vehicles<br />

between the initial start and the current end of the queue do no longer meet<br />

the queue condition (having a speed > End speed).<br />

Queue length is output in units of length not in number of cars.<br />

The queue is still monitored as long as there is a “queue remainder” - even<br />

if the first vehicles directly upstream of the queue counter are not in queue<br />

condition any more.<br />

The maximum queue length reaches to the next queue counter located at<br />

an upstream position. Queue counters created automatically for node<br />

evalulations are not regarded.<br />

Definition<br />

Queue counters can be placed at any position within a link/connector. The<br />

most suitable position is at the stop lines of a signalized intersection.<br />

To define queue counters follow the steps outlined below:<br />

1. Select the Queue Counters mode.<br />

2. With a single left mouse click select on the link the location of the queue<br />

counter.<br />

3. Define the location of the queue counter within the link by clicking the<br />

right mouse button at the desired location. Queues will be measured<br />

upstream from this location.<br />

4. Enter a number in the appearing window and choose OK.<br />

Configuration<br />

In order to get the desired output data additional information is needed. This<br />

is to be provided within the Queue Measurement - Configuration window<br />

(see below) which is accessible by pressing the CONFIGURATION button in<br />

EVALUATION – FILES… once the option Queue Length is active.<br />

The following data can be defined:<br />