Poster Sessions<br />

2615. Respiratory Navigator-Triggered, Multi-Slice Turbo Spin Echo with Motion-Sensitized Driven<br />

Equilibrium Prepulse: A Novel Sequence for Black-Blood T 2 -Weighted Imaging of Liver<br />

Gregory James Wilson 1,2 , George R. Oliveira 2 , Jeffrey Harold Maki, 2,3<br />

1 MR Clinical Science, Philips Healthcare, Cleveland, OH, United States; 2 Radiology, University of Washington, Seattle, WA, United<br />

States; 3 Radiology, Puget Sound VA HCS, Seattle, WA, United States<br />

Black-blood (BB) T2-weighted (T2w) imaging can provide increased liver lesion conspicuity over standard bright-blood T2w imaging. The sequence<br />

evaluated here uses respiratory navigator-triggering and a motion-sensitized driven equilibrium (MSDE) pre-pulse with a multi-slice turbo spin echo (TSE)<br />

readout. This sequence provides BB T2w images with high TSE image quality and without EPI distortions. In this study, various motion-sensitizing gradient<br />

directions and strengths were evaluated.<br />

2616. Single Breath-Hold High Spatial Resolution Abdominal Imaging and T2* Mapping at 7.0 T<br />

Matthias Alexander Dieringer 1,2 , Fabian Hezel 1 , Wolfgang Renz, 1,3 , Philipp Boyé, 12 , Bernd Ittermann, 1,4 ,<br />

Frank Seifert, 1,4 , Tomasz Lindel, 1,4 , Thoralf Niendorf 1,2<br />

1 Berlin Ultrahigh Field Facility, Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany; 2 Experimental and Clinical<br />

Research Center (ECRC), Charité Campus Buch, Humboldt-University, Berlin, Germany; 3 Siemens Healthcare, Erlangen, Germany;<br />

4 Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany<br />

Abdominal imaging examinations constitute a growing fraction of clinical MRI exams. Since ultrahigh field magnetic resonance imaging becomes more<br />

widespread, a range of applications established in the clinical scenario at 1.5 T and 3.0 T is emerging at 7.0 T. An eight channel transceiver surface coil array<br />

together with a 2D fast gradient echo sequence delivered high details of abdominal sub-millimeter anatomic structures, such as the gallbladder wall and<br />

subtle liver vessels without the application of contrast agent, and enabled T2*-Mapping of the liver at 7.0 T.<br />

2617. MR Imaging of the Human Biliary Tree Using a Flexible Catheter-Mounted Radio-Frequency Detector<br />

Microcoil<br />

Christopher Antony Wadsworth 1 , Shahid A. Khan 1 , Simon D. Taylor-Robinson 1 , Wladyslaw M W Gedroyc 2 ,<br />

Munir M. Ahmad 3 , Richard R. A. Syms 3 , Ian R. Young 3<br />

1 Department of Hepatology & Gastroenterology, Imperial College, London, United Kingdom; 2 MRI Unit, Imperial College Healthcare<br />

NHS Trust, London, United Kingdom; 3 Department of Electrical and Electronic Engineering, Imperial College, London, United<br />

Kingdom<br />

Problem: Strictures in the biliary tree are difficult to characterise as benign or malignant. A RF receiver microcoil applied directly to the biliary tree should<br />

improve MRI resolution substantially. Method: An innovative flexible catheter mounted microcoil has been developed. This was used as the receiver coil in<br />

MR imaging of a resected liver and biliary tree. Results: High resolution images were obtained. Signal to noise ratios and resolution were substantially better<br />

with the microcoil than with the standard coil. Conclusion: A prototype RF microcoil receiver can produce high quality images of ex vivo human liver tissue.<br />

These images demonstrate interpretable anatomical detail with sub-millimetre resolution and are superior to those obtained using a standard body coil.<br />

2618. High Spatial and Temporal Resolution Perfusion Imaging of Hepatocellular Carcinoma with Time-<br />

Resolved 3DPR Using a 32-Channel Coil at 3T<br />

Ethan K. Brodsky 1,2 , Walter F. Block 2,3 , William Schelman 4,5 , Scott B. Reeder 1,2<br />

1 Radiology, University of Wisconsin, Madison, WI, United States; 2 Medical Physics, University of Wisconsin, Madison, WI, United<br />

States; 3 Biomedical Engineering, University of Wisconsin, Madison, WI, United States; 4 Carbone Cancer Center, University of<br />

Wisconsin, Madison, WI, United States; 5 Medicine, University of Wisconsin, Madison, WI, United States<br />

Detection, characterization, and monitoring of hepatocellular carcinoma (HCC) is challenging due to its variable and rapid arterial enhancement. The ability<br />

to monitor changes in both morphology and perfusion is essential for evaluating the effectiveness of anti-angiogenic therapies. Multiple-phase CE-MRI has<br />

traditionally been used, but suffers from limited temporal resolution and an inability to consistently match acquisitions to the desired enhancement phase.<br />

We demonstrate the feasibility of contrast-enhanced isotropic-resolution 3DPR acquisition at 3T using a 32-channel coil with real-time monitoring that<br />

allows breath-holds to be matched to the desired enhancement phase and enables retrospective selection of the temporal window showing optimal lesion<br />

contrast.<br />

2619. Contrast Uptake Enhancement Patterns in Neuroendocrine Liver Metastases<br />

Choon Hua Thng 1 , Tong San Koh 2 , Septian Hartono 1 , Puor Sherng Lee 1 , Keiko Miyazaki 3 , David Collins 3 ,<br />

Martin O. Leach 3 , Val Lewington 4 , Dow-Mu Koh 4<br />

1 National Cancer Centre Singapore, Singapore, Singapore; 2 Nanyang Technological University, Singapore, Singapore; 3 CRUK-<br />

EPSRC Cancer Imaging Centre, Institute of Cancer Research, Sutton, United Kingdom; 4 Royal Marsden NHS Foundation Trust,<br />

Sutton, United Kingdom<br />

Neuroendocrine liver metastases have been described as being hypervascular in nature, showing arterial enhancement and washout. However, other<br />

enhancement patterns have been observed in clinical practice (plateau and progressive enhancement). Three types of enhancement curves in neuroendocrine<br />

tumor was found: (1) Rapid increasing followed by decrease, (2) Rapid increasing followed by plateau, and (3) Progressively increasing. Type I pattern<br />

show higher intravascular volume (v1) compared to percentage of interstitial volume (v2). Type II and III pattern show higher v2 compared to v1. Type I<br />

pattern show higher blood flow (F) compared to Type II/III.