0.6 SAFETY NOTICE<br />
This Safety Notice has been included to<br />
emphasize the DANGER OF<br />
HAZARDOUS VOLTAGES on the REAR<br />
TERMINAL PANEL of your instrument.<br />
USE EXTREME CAUTION WHEN<br />
INSTALLING OR SERVICING your instrument.<br />
Please read the entire contents<br />
of the Installation and Wiring Chapter of<br />
this manual before attempting to install or<br />
service your instrument.<br />
ELECTRICAL SHOCK HAZARD<br />
MAY CAUSE INJURY OR DEATH<br />
Use extreme caution when servicing the<br />
rear terminal panel of your instrument.<br />
Refer to the page numbers listed below<br />
for information on performing the following<br />
functions:<br />
• Connecting Power - See pages 2-4 and 2-5<br />
• Wiring Signal Input Connections - See pages 2-<br />
5 through 2-7<br />
• Wiring Contact Output Connections - See page<br />
2-7<br />
Siemens AG C79000-G7374-C211-01<br />
<strong>SIREC</strong> D Manual<br />
POWER INPUTS<br />
WARNING<br />
Introduction<br />
The mains voltage is connected via an<br />
appliance plug whose PE conductor is connected<br />
to the housing.<br />
The appliance plug must be readily accessible<br />
and is used to isolate the recorder<br />
from the power supply.<br />
SIGNAL INPUTS<br />
WARNING<br />
Use extreme caution when wiring signal input<br />
connections. Hazardous potentials may<br />
exist on signal input terminals, which are<br />
floating, with respect to instrument ground.<br />
These hazardous potentials may be exposed<br />
inside the instrument case and on<br />
the Rear Terminal Panel of your instrument.<br />
Any voltage potential at the signal source<br />
will exist on the instrument's respective signal<br />
input terminal; e.g. power generator<br />
stator winding temperature monitoring<br />
thermocouples.<br />
CONTACT OUTPUT TERMINALS<br />
WARNING<br />
Use extreme caution when wiring contact<br />
output connections. Hazardous potentials<br />
may exist on contact output terminals,<br />
which are floating, with respect to instrument<br />
ground. These hazardous potentials<br />
may be exposed inside the instrument case<br />
and on the Rear Terminal Panel of your instrument.<br />
Any voltage potentials at the<br />
contact circuit will exist on the instrument's<br />
respective contact output terminals; e.g.<br />
line-powered circuits.<br />
0-3