Programming<br />

4-32<br />

a. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight “Decimal fix” and press ENTER.<br />

b. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight the desired number of decimal places<br />

required and press ENTER.<br />

4. Programming Basepoint - A Basepoint must<br />

be established to perform the Moving Average<br />

calculations on.<br />

a. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight “Basepoint” and press ENTER.<br />

b. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight the desired point to be the basepoint<br />

and press ENTER.<br />

5. Programming Time Period - The Time Period<br />

is the time base used to set the duration (time) of<br />

the moving window. The point does not become<br />

valid until this time has elapsed.<br />

a. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight "Time period" and press ENTER. The<br />

display reads "minutes�XXXX�”.<br />

b. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

select the digit and the LEFT (�) or RIGHT (�)<br />

Arrow Keys to move to a position to enter the<br />

desired Time Period. A maximum 1440 minutes<br />

(24 hours) may be entered. When the desired<br />

Time Period is displayed, press ENTER and the<br />

display returns to "Time Period".<br />

6. Programming Engineering Units - Up to a<br />

five character engineering units message may be<br />

assigned for Calculated points.<br />

a. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight “Eng units” and press ENTER.<br />

b. Use the Alphanumeric keypad to enter the<br />

desired Engineering Units message and press<br />

ENTER.<br />

7. Alarms - Refer to Alarms Setup in Paragraph<br />

4.6.14 below for instructions on programming<br />

alarms.<br />

8. Assigning a Point to a Chart Scale - Each<br />

point must be assigned to a Chart Scale.<br />

a. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight “Chart scale” and press ENTER.<br />

b. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

select the Chart Scale numeral and press<br />

ENTER. To leave the programming menu, press<br />

EXIT until the “Command” prompt is displayed.<br />

G. Gated Timer - The Gated Timer function<br />

allows a timer, measuring in seconds, to be<br />

controlled by a ‘gate’ from a logic point. For<br />

example, if a point is measuring temperature and<br />

you wanted to know the total amount of time the<br />

temperature measured by this point is above or<br />

below a certain level, a Conditional Point can be<br />

programmed to be ‘true' only when the temperature<br />

is above or below a set level. A Gated Timer Point<br />

can then be programmed to be turned ON only<br />

when the Conditional Point is in the true state. The<br />

Gated Timer Point will then only be timing when the<br />

temperature is above or below a set level. The timer<br />

will continue to accumulate time, in seconds, each<br />

time it is turned on. The Gated Timer Point can be<br />

reset at programmable time intervals and alarms<br />

can be set to alarm if the timer total goes above a<br />

programmed time interval in seconds.<br />

1. Programming Parameters - The following<br />

steps detail programming from the Main Menu:<br />

a. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight “Prog point” and press ENTER.<br />

b. Use the numeric keypad to enter the point to<br />

be programmed, 1 to 9 or A to C and press<br />

ENTER.<br />

c. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight the desired point option and press<br />

ENTER.<br />

d. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight “Calculated” and press ENTER.<br />

e. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight “Gated timer” and press ENTER.<br />

2. Programming Point Tag - Up to a ten character<br />

alphanumeric label can be assigned to each<br />

point.<br />

a. Use the UP (↑) or DOWN (↓) Arrow Keys to<br />

highlight “Point tag” and press ENTER.<br />

b. Use the alphanumeric keypad to enter the<br />

desired Point Tag and press ENTER.<br />

Siemens AG C79000-G7374-C211-01<br />

<strong>SIREC</strong> D Manual