General Description<br />

1.5 OPTIONS<br />

1.5.1 General. Additional functions and capabilities<br />

can be added to the <strong>Display</strong> <strong>Recorder</strong> as<br />

options. These options are briefly described in the<br />

following paragraphs.<br />

1.5.2 Digital Input and Output - This option<br />

provides six form C (Normally Open, Common,<br />

Normally Closed contacts) Relay outputs capable<br />

of switching 250 VAC and three isolated digital<br />

inputs. The relay outputs can be programmed to<br />

respond to alarm events while the digital inputs can<br />

be used to trigger events such as changing recording<br />

speeds or stopping and starting recording.<br />

Table 1-1 Specifications<br />

OPERATING<br />

1-4<br />

Input Signals<br />

1.5.3 Memory Modules (PCMCIA<br />

Cards) - Several sizes of Memory Modules<br />

(PCMCIA Cards) are available for your recorder.<br />

The optional memory modules are available in<br />

either static ram or flash ram configuration. The<br />

<strong>Recorder</strong> supports both types of memory cards in<br />

configurations of up to 20 Megabytes in size which<br />

will allow up to 10,000,000 data samples.<br />

1.5.4 Communications Interface -<br />

Two communications options are available. An<br />

ESD protected RS232 interface and an isolated<br />

RS485 interface. The RS232 interface allows portable<br />

computers to easily interface with the <strong>Recorder</strong>.<br />

Communications speed is selectable from<br />

300 to 19200 baud. Communication language is<br />

Modbus RTU or Modbus ASCII.<br />

1.5.5 Seismic Qualification - The <strong>Display</strong><br />

<strong>Recorder</strong> is available with an IEEE 344 Seismic<br />

Qualification. A seismic qualification report<br />

(IEEE 344) and all required seismic hardware are<br />

furnished with this option.<br />

1.6 SPECIFICATIONS<br />

1.6.1 General. <strong>Recorder</strong> specifications are<br />

shown in Table 1-1 as follows:<br />

DC Voltage: Linear and square root . Full scale ranges: +100mV, +1V, and +10V DC<br />

Current: 4 to 20mA, 10 to 50mA. Dry Contact or External Input (Serial)<br />

Thermocouple: J, K, T, E, R, S, B, C, Nicrosil Nisil, and Nickel/Moly<br />

RTD (Option): 10 ohm Cu, 100 ohm Pt 385, 100 ohm Pt 392, 200 ohm Pt 385, 200 ohm Pt<br />

392, and 120 ohm Ni .<br />

Input Accuracy Voltage: ±0.05% of programming range<br />

Current: ±0.5% using internal shunts, +0.1% using external shunt Part No. MAS-50R0<br />

Thermocouple: ±1.5°C for J, K, T, E, Nicrosil-Nisil, and Nickel/Nickel Moly; ±3°C for R, S,<br />

and C; ±4°C for B. RTD: ±0.5°C<br />

Input Resolution 0.006% of full scale<br />

Input Impedance >10 megohms on 100mV, 1V Ranges, ~50k on 10 Volt Range<br />

Input Capacity Standard: 6 or 12 direct<br />

Common Mode Voltage 250 Vdc or peak Vac<br />

Common Mode Noise Rejection >100 dB, 50/60 Hz<br />

Normal Mode Noise Rejection >50 dB at 50/60 Hz<br />

EMC Compliance Meets or exceeds the requirements of CE for EMC 89/336/EEC<br />

Siemens AG C79000-G7374-C211-01<br />