Critical State Error Messages<br />

5. Enter the new password.<br />

6. Go back to the Status page and click the monitor group of the<br />

system.<br />

7. Click the Enabled checkbox to disable the monitor.<br />

8. Click the Disabled checkbox to enable the monitor and wait for<br />

the metrics to resample.<br />

Remote procedure call failed (Windows only)<br />

This error message may occur when <strong>OneSight</strong> had trouble reauthenticating<br />

its connection with the system after the system was<br />

rebooted. While viewing the monitor on the status page, click the<br />

Enabled button to disable the monitor. The monitor will move to the<br />

bottom of the list in the monitor group. Click the Enabled button to<br />

enable the monitor, forcing <strong>OneSight</strong> to re-authenticate with the<br />

system.<br />

Failed to load Perfmon name table (Windows only)<br />

This error message may occur when <strong>OneSight</strong> had trouble reauthenticating<br />

its connection with the system after the system was<br />

rebooted. While viewing the monitor on the status page, click the<br />

Enabled button to disable the monitor. The monitor will move to the<br />

bottom of the list in the monitor group. Click the Enabled button to<br />

enable the monitor, forcing <strong>OneSight</strong> to re-authenticate with the<br />

system.<br />

Missing counter value (Windows only)<br />

This message occurs when the indicated Windows perfmon metric<br />

does not exist on this system. In most cases, this is a system process<br />

that has stopped running. To resolve this problem:<br />

1. Log onto the system that is displaying the error message.<br />

2. From the Start menu, click Run and enter perfmon.<br />

920 <strong>OneSight</strong> <strong>Administrator</strong> <strong>Guide</strong>