acked acetabular cups. Clin Orthop Relat<br />

Res 1995;319:317-26.<br />

7 Schmalzried TP, Jasty M, Harris WH.<br />

Periprosthetic bone loss in total hip arthroplasty:<br />

polyethylene wear debris and the<br />

concept of the effective joint space. J Bone<br />

Joint Surg Am 1992;74-A:849-63.<br />

8 Currier BH, Currier JH, Mayor MB, et al.<br />

Evaluation of oxidation and fatigue damage<br />

of retrieved crossfi re polyethylene<br />

acetabular cups. J Bone Joint Surg Am<br />

2007;89:2023-9.<br />

9 Tower S, Currier JH, Currier BH, et al.<br />

Rim cracking of the cross-linked longevity<br />

polyethylene acetabular liner after total<br />

hip arthroplasty. J Bone Joint Surg Am<br />

2007;89:2212-7.<br />

10 Jarrett CA, Ranawat AS, Bruzzone M, et al.<br />

The squeaking hip: a phenomenon of ceramic-on-ceramic<br />

total hip arthroplasty. J Bone<br />

Joint Surg Am 2009;91:1344-9.<br />

11 Wagner H, Wagner M. German clinical<br />

results whit metasul bearings. In: Rieker C,<br />

Windler M, Wyss U, eds. Metasul: a metalon-metal<br />

bearing. Bern: Hans Huber 1999.<br />

12 Delaunay C, Petit I, Learmonth ID, et al. Metalon-Metal<br />

bearings total hip arthroplasty: The<br />

cobalt and chromium ions release concern.<br />

Orthop Traumatol Surg Res 2010;96:894-<br />

904.<br />

13 Unsworth A, Dowson D, Wright V. Some<br />

new evidence on human joint lubrication.<br />

Ann Rheum Dis 1975;34:277-285.<br />

14 Scholes SC, Unsworth A, Blamey JM, et al.<br />

Design aspects of compliant soft layer bearings<br />

for an experimental hip prosthesis. Proc<br />

Instn Mech Engrs H 2005;219:79-87.<br />

15 Dowson D. Basic tribology. In: Dowson D,<br />

Wright V, eds. An introduction to the biomechanics<br />

of joints and joint replacement. London:<br />

Mechanical Engineering Publications<br />

Limited 1981.<br />

16 Unsworth A, Roberts B, Thompson JC. The application<br />

of soft-layer lubrication to hip prostheses.<br />

J Bone Joint Surg Br 1981;63:297.<br />

17 Unsworth A, Dowson D, Wright V. The frictional<br />

behaviour of human synovial joints<br />

– Part 1: natural joints. Trans. ASME J Lubr<br />

Technol 1975;97,369-376.<br />

18 Dowson D, Jin ZM. Micro-elastohydrodynamic<br />

lubrication of synovial joints. Eng Med<br />

1986;15:63-5.<br />

19 Unsworth A, Pearcy MJ, White EFT, et al. Soft<br />

layer lubrication of artifi cial hip joints. In: Procee<strong>di</strong>ngs<br />

of IMechE International Conference<br />

of Fifty years on. London: Mechanical Engineering<br />

Publications 1987, pp. 715-24.<br />

20 Burgess IC. Tribological and mechanical<br />

properties of compliant bearings in total joint<br />

iMpiEgo dEL poLicarBonato-urEtano<br />

nELL’artropLastica dELL’anca s55<br />

replacement. Dissertation, University of Durham<br />

1997.<br />

21 Yao JQ, Unsworth A. Asperity lubrication<br />

of human joints. Proc. Instn Mech Engrs H<br />

1993;207:245-54.<br />

22 Smith SL, Ash HE, Unsworth A. A tribological<br />

study of UHMWPE acetabular cups and<br />

polyurethane compliant layer cups. J Biomed<br />

Mater Res 2000;53:710-6.<br />

23 Bigsby RJA, Auger DD, Jin ZM, et al. A<br />

comparative tribological study of the wear<br />

of composite cushion cups in a physiological<br />

hip joint simulator. J Biomechanics<br />

1998;31:363-9.<br />

24 Townley CO. Hemi and total articular replacement<br />

arthroplasty of the hip with<br />

the fi xed femoral cup. Ortho Clin N Am<br />

1982;13:869-94.<br />

25 Charnley J. The long-term results of lowfriction<br />

arthroplasty of the hip performed as<br />

a primary intervention. J Bone Joint Surg Br<br />

1972;54:61-76.<br />

26 Scholes SC, Inman IA, Unsworth A, et al.<br />

Tribological assessment of a fl exible carbonfi<br />

bre reinforced poly(ether-ether-ketone)<br />

acetabular cup articulating against an alumina<br />

femoral head. Proc Inst Mech Eng H<br />

2008;222:273-83.<br />

27 Scholes SC, Unsworth A. Wear stu<strong>di</strong>es on<br />

the likely performance of CFR-PEEK/CoCrMo<br />

for use as artifi cial joint bearing materials. J<br />

Mater Sci Mater Med 2009;20:163-70.<br />

28 St. John KR, Gupta MN. Wear resistance of<br />

polycarbonate urethane acetabular cups as<br />

compared to cross-linked ultra high molecular<br />

weight polyethylene. Society for Biomaterials<br />

Annual Meeting 2010.<br />

29 Elsner JJ, Mezape Y, Hakshur K, et al. Wear<br />

rate evaluation of a novel polycarbonate-urethane<br />

cushion form bearing for artifi cial hip<br />

joints. Acta Biomater 2010;6:4698-707.<br />

30 Steenbrugge F, Govaers K, Van Nieuwenhuyse<br />

W, et al Displaced femoral neck fractures<br />

in adult and elderly patients, pitfalls<br />

in treatment options: internal fi xation or<br />

replacement? Acta Orthop Traum Turcica<br />

2000;34:430-3.<br />

31 Sierra RJ, Cabanela ME. Conversion of failed<br />

hemiarthroplasties after femoral neck fractures.<br />

Clin Orthop Relat Res 2002;(399):129-<br />

39.<br />

32 Gilbert M, Capozzi J. Unipolar or bipolar<br />

prosthesis for the <strong>di</strong>splaced intracapsular hip<br />

fracture? An unanswered question. Clin Orthop<br />

Relat Res 1998;(353):81-5.<br />

33 Lachiewicz PF, Soileau ES. Stability of Arthroplasty<br />

in Patients 75 years or older. Clin<br />

Orthop Relat Res 2002;(405):65-9.<br />

34 Steinberg M, Corces A, Fallon M. Acetabular<br />

involvement in osteonecrosis of the femoral<br />

head. J Bone Joint Surg Br 1999;81:60-5.<br />

35 Lester DK, Wertenbruch JM, Piatkowski<br />

AM. Degenerative changes in normal<br />

femoral heads in the elderly. Arthroplasty<br />

1999;14:200-3.<br />

36 Siebert WE, Mai S, Kurtz S. Retrieval analysis<br />

of a polycarbonate-urethane acetabular<br />

cup: a case report. J Long Term Eff Med Implants<br />

2008;18:69-74.<br />

37 Wippermann B, Kurtz S, Hallab N, et al. Explantation<br />

and analysis of the fi rst retrieved<br />

human acetabular cup made of polycarbonateurethane:<br />

a case report. J Long Term Eff<br />

Med Implants 2008;18:75-83.<br />

38 Bhandari M, Devereaux PJ, Swiontkowski<br />

MF, et al. Internal fi xation compared with<br />

arthroplasty for <strong>di</strong>splaced fractures of the<br />

femoral neck. A meta-analysis. J Bone Joint<br />

Surg Am 2003;85:1673-81.<br />

39 Dunstan E, Ladon D, Whittingham-Jones<br />

P, et al. Chromosomal aberrations in the<br />

peripheral blood of patients with metalon-metal<br />

bearings. J Bone Joint Surg Am<br />

2008;90:517-22.<br />

40 Murphy SB, Ecker TM, Tannast M. Two- to<br />

9-year clinical results of alumina ceramicon-ceramic<br />

THA. Clin Orthop Relat Res<br />

2006;453:97-102.<br />

41 Willmann G. Ceramic femoral head<br />

retrieval data. Clin Orthop Relat Res<br />

2000;379:22-8.<br />

42 Yang CC, Kim RH, Dennis DA. The squeaking<br />

hip: a cause for concern-<strong>di</strong>sagrees. Orthopae<strong>di</strong>cs<br />

2007;30:739-42.<br />

43 Ranawat AS, Ranawat CS. The squeaking<br />

hip: a cause for concern-agrees. Orthopae<strong>di</strong>cs<br />

2007;30:738-43.<br />

44 Taylor S, Manley M, Sutton K. The role of<br />

stripe wear in causing acoustic emissions<br />

from alumina ceramic-on-ceramic bearings.<br />

J Arthroplasty 2007;22:47-51.<br />

45 Smith RA, Hallab NJ. In vitro macrophage<br />

response to polyethylene and polycarbonateurethane<br />

particles. J Biomed Mater Res A<br />

2010;93(1):347-55.<br />

46 Smith RA, Maghsoodpour A, Hallab NJ. In<br />

vivo response to cross-linked polyethylene<br />

and polycarbonate-urethane particles. J<br />

Biomed Mater Res A 2010;93:227-34.<br />

47 Burroughs BR, Hallstrom B, Golladay GJ, et al.<br />

Range of motion and stability in total hip arthroplasty<br />

with 28, 32, 38 and 44 mm femoral<br />

heads. J Arthroplasty 2005;20:11-19.<br />

48 Berry DJ, von Klnock M, Schleck CD, et al.<br />

Effect of femoral head <strong>di</strong>ameter and operative<br />

approach on risk of <strong>di</strong>slocation after primary<br />

total hip arthroplasty. J bone Joint Surg<br />

Am 2005;87:2456-63.