<strong>ITT</strong>7528, <strong>ITT</strong>7529<br />

DUAL SENSE AMPLIFIERS WITH<br />

PREAMPLIFIER TEST PONTS<br />

SWITCHING CHARACTERISTICS, Vcc+ = 5 V, Vcc- = ~5 V, TA = 25eC<br />

Propagation Delay Times<br />

Test<br />

Symbol From Input To Output Fig. Min Typ Max Unit Test Conditions<br />

tPLH(D) A1-A2 W 25 40 ns CL - 15 pF, RL - 2880<br />

39<br />

tPHL(D) 20 ns<br />

tPLH(S) Strobe W 15 30' ns CL = 15 pF, RL = 2880<br />

39<br />

tPHL(S) 20 ns<br />

TYPICAL RECOVERY AND CYCLE TIMES, Vcc - = -5 V, Vcc - = -5 V, TA = 25°C<br />

torD<br />

torc<br />

t.y.(mln)<br />

Parameter<br />

Differential-input overload<br />

recovery time<br />

(see Note 5)<br />

Common-mode-input overload<br />

recovery time (see Note 6)<br />

Minimum cycle time<br />

Min<br />

,Typ<br />

Max Unit Test Conditions<br />

20 ns Differential Input Pulse:<br />

VID = 2 V, tr = 20 ns<br />

20 ns Common-Mode Input Pulse:<br />

V~c = ±2V, tr = tr = 20 ns<br />

200 ns<br />

NOTES:<br />

3. The differential-input threshold voltage (VT )<br />

is defined as the d-c differential-input voltage<br />

(VID) required to force the output <strong>of</strong> the sense<br />

amplifier to the logic gate threshold voltage<br />

level.<br />

4. Common-mode input firing voltage is the<br />

minimum common-mode voltage that will exceed<br />

the dynamic range <strong>of</strong> the 'input at the<br />

specified conditions and cause the logic output<br />

to switch. The specifed common-mode input<br />

signal is applied with a strobe-enable present.<br />

5. Differential-input overload recovery time<br />

is the time necessary for the device to recover<br />

from the specified common-mode-input overlo~d<br />

signal prior to the strobe-enable signal.<br />

6. Common"mode~inputoverloadrecovery time<br />

is the time necessary for the device to recover<br />

from the speCified common-mode-input overload<br />

signal prior to the strobe-enable signal.<br />

6-17 ..