<strong>ITT</strong><br />

1 N4383/5, 1 N4585/6, RG1122/3<br />

i-AMP GLASS RECTIFIERS<br />

- -----<br />

SEMICOND.UCTORS<br />

1-AMP SILICON<br />

GLASS RECTIFIERS<br />

• VR<br />

Ratings 50 to 1000 Volts<br />

• Surge Current Rating 50 Amperes<br />

• Series JAN approved<br />

The <strong>ITT</strong>1N4383-5, 1 N4585-6, <strong>of</strong>fer up to oneamp<br />

rectified current at 100°C in a small, hermetically<br />

sealed 00-29 glass package. All units<br />

are passivated, 100 percent tested, and have<br />

a 50-amp surge current rating to insure a stable,<br />

highly reliable rectifier. Rectifiers are supplied<br />

with solderable leads and may be delivered<br />

reel-packed for automatic insertion<br />

equipment.<br />

ABSOLUTE MAXIMUM RATINGS·<br />

Characteristics<br />

RGl122<br />

Maximum recurrent peak reverse voltage .. 50<br />

Maximum RMS voltage ................ 35<br />

Maximum DC blocking voltage .......... 50<br />

Maximum average forward rectified<br />

current '/a" lead length .. 50°C Ambient 1.0<br />

100°C Ambient 1.0<br />

150°C Ambient 0.3<br />

Maximum peak surge 1 Cycle 50<br />

overload current 10 Cycles 16<br />

100 Cycles 6<br />

Maximum forward voltage drop<br />

at 1 amp DC, 25°C ................. 1.0<br />

Maximum full cycle average reverse<br />

current, @ rated average forward<br />

current and 100°C ambient .......... 275<br />

Maximum DC leakage at rated DC<br />

blocking voltage and 25°C ambient ... 10<br />

Typical recovery time at 2SoC ambient ... 10<br />

Temperature Range, op & stg ...........<br />

RGl123 lN4383 lN4384 lN4385 lN4585 lN4586' Units<br />

100 200 400 600 800 1000 Volts<br />

70 140 280 420 560 700 Volts<br />

100 200 400 600 800 100 Volts<br />

1.0 1.0 1.0 1.0 1.0 1.0 Amps<br />

1.0 1.0 1.0 1.0 0.6 0.6 Amps<br />

0.3 0.3 0.3 0.3 0.2 0.2 Amps<br />

50 50 50 50 50 50 Amps<br />

16 16 16 16 16 16 Amps<br />

6 6 6 6 6 6 Amps<br />

1.0 1.0 1.0 1.0 1.0 1.0 Volts<br />

250 275 250 225 200 200 "amps<br />

10 10 10 10 10 10 ramps<br />

10 10 10 10 10 10 ",secs<br />

-65 to +175 °C<br />

NOTE:<br />

60 cps, inductive or resistive load, single phase<br />

half wave.<br />