<strong>ITT</strong>75234, <strong>ITT</strong>75235<br />

DUAL SENSE AMPLIFIERS<br />

SWITCHING CHARACTERISTICS, Vcc+ = 5V, Vcc -<br />

Test<br />

Symbol From Input To Output Fig. Min Typ Max Unit Test Conditions<br />

tPLH(n) A1-A2 W 25 ns CL = 15pF, RL = 288 fl<br />

40<br />

tpHL(n) 25 40 ns<br />

tPLH(s) STROBE -<br />

W 25 ns CL<br />

40<br />

tPHL(s) 15 30 ns<br />

-<br />

15pF,<br />

RL = 288 fl<br />

TYPICAL RECOVERY AND CYCLE TIMES, Vcc+ = 5V, Vcc - = 5V, TA = 25°C<br />

tORD<br />

tORC<br />

tcyc(min)<br />

Parameter<br />

Differential-input overload<br />

recovery time (see Note 5)<br />

Common-made-input overload<br />

recovery time (see Note 6)<br />

Minimum cycle time<br />

Min Typ Max Unit Test Conditions<br />

20 ns Differentiai Input Pulse:<br />

VID = 2 V,<br />

tr = tf = 20 ns<br />

20 ns Common-Mode Input Pulse<br />

VIC = ±2 V,<br />

200 ns tr - tf - 20 ns<br />

NOTES:<br />

5. Differential-input overload recovery time<br />

is the time necessary for the device to recover<br />

from the specified common-made-input overload<br />

signal prior to the strobe-enable signal.<br />

6. Common-made-input overload recovery time<br />

is the time necessary for the device to recover<br />

from the specified common-made-input overload<br />

signal prior to the strobe-enable signal.<br />

6-24