10.12.2012 Views

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4<br />

5<br />

90 Modeling with Circuit Components<br />

� � «Use pin»<br />

If the box is checked, the Source current is defined by the quantity connected to the pin, otherwise<br />

the value in the text box is used.<br />

� � «Partial Derivation»<br />

If the box is checked, the improved partial derivation algorithm is effective. In few cases,<br />

when the source value is defined with a equation, instabilities are possible. Clear the box to<br />

avoid the problem.<br />

� «Time Controlled»<br />

The predefined time-controlled current source is selected. In the list, select a time function<br />

and define the corresponding parameters. See also “Using Time Functions” on page 275.<br />

� In the list, select the sine, pulse, triangular, trapezoidal, saw-tooth rising, or saw-tooth falling<br />

time function.<br />

AC Parameters<br />

� «Phase & Magnitude»<br />

The Phase/Magnitude representation is selected. Common parameter types. Enter a numerical<br />

value, a variable, or an expression in the text box. See also “AC Simulation Models” on<br />

page 401.<br />

� «Angular Dimension»<br />

In the list, select radians or degrees for the angular dimension of the phase.<br />

� «Real & Imaginary»<br />

The Real/Imaginary representation is selected. Common parameter type. Enter a numerical<br />

value, a variable, or an expression in the text box.<br />

Linear Current Source<br />

it () =<br />

I<br />

The value of the source current is equivalent to the present value of the quantity specified in<br />

the text box. Usually a constant value, a time function, or a variable are chosen, or the value<br />

is determined in a state graph. All system quantities and variables can be combined with<br />

mathematical and logical operators and constants.<br />

However, the expression must be technically meaningful. If it is not, numerical instability or<br />

completely wrong results are possible.In particular, sudden changes in the first derivation of<br />

the control quantity should be avoided.<br />

The voltage of an ideal current source is arbitrary. Real current sources have always an internal<br />

resistance. If the internal resistance is essential for the simulation target, a corresponding<br />

resistance must be connected in parallel.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Source Current [A] IS real<br />

Partial Derivation Flag (1: On; 0: Off) PARTDERIV real<br />

EMF Magnitude [A] AC_MAG real<br />

EMF Phase Shift [deg] AC_PHASE real