<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 315<br />

By default, components and wires of the magnetic domain are represented in orange in the<br />

graphical representation of the Schematic. Select SHEET>PROPERTIES to change the wire color<br />

of the domain. You can only change the wire color. The symbol color is not affected by the setting.<br />

Magneto-Motive Force Source<br />

>>Basics>Physical Domains>Magnetic<br />

The component represents an ideal magneto-motive force source which supplies the defined<br />

magnetic force for an arbitrary magnetic flux. Within the dialog you can choose a constant or<br />

time-controlled source.<br />

Dialog Settings<br />

� «Magneto-Motive Force [A]»<br />

The linear magneto-motive force source is selected. Common parameter type. Enter a numerical<br />

value, a variable, or an expression in the text box or use the pin to connect a quantity.<br />

� � «Use pin»<br />

If the box is checked, the value is defined by the quantity connected to the pin, otherwise the<br />

value in the text box is used.<br />

� «Time Controlled»<br />

The time-controlled magneto-motive force source is selected. In the list, select a time function<br />

and define the corresponding parameters. See also “Using Time Functions” on page 275.<br />

� In the list, select the sine, pulse, triangular, trapezoidal, saw-tooth rising, or saw-tooth falling<br />

time function.<br />

Linear Magneto-Motive Force Source<br />

MV() t =<br />

VALUE<br />

The magneto-motive force is equivalent to the present value of the quantity specified in the<br />

text box. Usually a constant value, a time function, or a variable are chosen, or the value is<br />

determined in a state graph. All system quantities and variables can be combined with mathematical<br />

and logical operators and constants.<br />

The magnetic flux of an ideal force source can be arbitrary. Real force sources have always<br />

an internal resistance. If the internal resistance is essential for the simulation target, a corresponding<br />

resistance must be connected in parallel.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Magneto-Motive Force [A] VALUE real<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Magneto-Motive Force [A] MV real<br />

Magnetic Flux [Vs] FLUX real