106 Modeling with Circuit Components<br />

Component Nodes<br />

Description Node Name Nature<br />

Pin 1 (with red point) N1 electrical<br />

Pin 2 N2 electrical<br />

Pin 3 N3 electrical<br />

Controlled Switch<br />

>>Basics>Circuit>Ideal Switches<br />

The component represent an ideal electrical switch. Within the dialog you can choose a voltage<br />

or current controlled switch.<br />

If the control quantity (V or I) is greater than threshold plus hysteresis, the controlled switch<br />

is on. If the control quantity is lower than threshold minus hysteresis, the controlled switch is<br />

off. Because it is an non-ideal switch, you can define an On and Off resistance for the line connection.<br />

The component cannot be used with AC and DC simulation.<br />

You cannot use zero for the on resistance.<br />

Off → On V or I > ( THRES + HYST)<br />

On → Off V or I < ( THRES – HYST)<br />

Dialog Settings<br />

� «Type»<br />

In the list, select Voltage or Current controlled switch.<br />

«On State Resistance»«Off State Resistance»<br />

Defines the resistance for the on and off state. Common parameter type. Enter a numerical<br />

value, a variable, or an expression in the text box or use the pin to connect a quantity.<br />

«Threshold Voltage»«Threshold Current»<br />

Defines the threshold of the controlled switch. Common parameter type. Enter a numerical<br />

value, a variable, or an expression in the text box.<br />

«Hysteresis Voltage»«Hysteresis Current»<br />

Defines the hysteresis of the controlled switch. Common parameter type. Enter a numerical<br />

value, a variable, or an expression in the text box.<br />

«Initial State»<br />

Defines the initial state of the controlled switch. Enter a numerical value, a variable, or an<br />

expression in the text box to define the initial state at simulation start.<br />

y<br />

THRES<br />

On<br />

Off<br />

HYST<br />

Control Quantity<br />