10.12.2012 Views

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4<br />

5<br />

100 Modeling with Circuit Components<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Voltage [V] V real<br />

Current [A] I real<br />

EMF Value [V] (voltage source) EMF real<br />

Source Current [A] (current source) IS real<br />

Derivative of Voltage [V/s] dV real<br />

Derivative of Current [A/s] dI real<br />

Component Nodes<br />

Description Node Name Nature<br />

Pin 1 (with red point) N1 electrical<br />

Pin 2 N2 electrical<br />

Multidimensional Table Source<br />

>>Basics>Circuit>Sources<br />

The multidimensional table source represents a table of controlled electrical sources (voltage<br />

and current) which depend on different, nonlinear input quantities. Each input quantity (node<br />

voltage or current of ammeter) has a specific characteristic with extrapolation type. The characteristics<br />

of input values can also be imported from a .mdx file created in the DAY Post Processor.<br />

Eeach defined source has two pins, whereas pin 0 and pin 1 belong to the first source,<br />

pin 2 and pin 3 to the seond source, an so on. Defined voltage sources have at the second pin<br />

the red point (N2 of standard voltage sources), current sources have at the first pin the red<br />

point (N1 of standard current sources).<br />

vn [ ] () t = – f( v( QUANT)<br />

[ m]<br />

, i( QUANT)<br />

[ m]<br />

)<br />

in [ ] () t =<br />

f( v( QUANT)<br />

[ m]<br />

, i( QUANT)<br />

[ m]<br />

)<br />

Dialog Settings<br />

«Name»<br />

Displays the component internal names of the input quantities which are defined in the<br />

dialog. You cannot make changes in these fields.<br />

«Input»<br />

The voltage/current of the defined quantities control the values of the sources. Quantity parameter<br />

type. The type accepts only a node potential or the current of an ammeters (e.g.<br />

N0003.V , AM2.I). The values cannot be assigned by a variable. Enter the quantity or use the<br />

pin to connect the quantity.<br />

� � «Use pin»<br />

If the box is checked, the control signal is defined by the quantity connected to the pin, otherwise<br />

the name in the text box is used.