Transferring Parameter Values into Graphical Subsheets<br />

<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 61<br />

Two non-conservative input pins<br />

To use mainsheet parameters in the subsheet you need non-conservative input pins. These<br />

input pins are able to transfer a mainsheet quantity into the subsheet.<br />

1 Choose SHEET>SUBSHEET OPEN to change into the subsheet wiring and choose «Create<br />

Pin/Parameters…» on the subsheet shortcut menu.<br />

2 Select Non-Conservative Node and define a name. Click to continue.<br />

3 Select «Input» and click to continue.<br />

4 Select the pin type. Please note: The type does not influence the parameter itself. It select<br />

only a proper symbol which is displayed in the parameter dialogs.<br />

Enter parameter type and<br />

default value<br />

5 Select the pin position. If you do not click any pin, you have to create the parameter transfer<br />

with a name reference in the mainsheet.<br />

6 The new pin symbol can now be connected with a parameter pin of a quantity in the subsheet.<br />

When no connection is used you can enter the pin name to transfer the mainsheet<br />

quantity.<br />

7 Choose «Level Up» in the subsheet shortcut menu to change to the next higher model level.<br />

Connect a mainsheet quantity with the pin or enter a name if the pin is disabled.