112 Modeling with Circuit Components<br />

Equivalent Line (MOSEQUL):<br />

The MOS characteristic is defined by an Equivalent<br />

line. You have to enter a value for the Forward voltage,<br />

Bulk resistance and Reverse resistance.<br />

Vlimit stands for the intersection of the forward and reverse<br />

characteristic and is calculated by the program itself.<br />

Exponential Function (MOSEXP):<br />

The MOS characteristic is defined by an Exponential<br />

function. You have to enter values for the Saturation<br />

current, Thermal voltage and Reverse resistance.<br />

XY Data Pairs (MOSXY)<br />

The MOS characteristic is defined by a data table. You can define the table within the characteristic<br />

dialog directly or load an existing file. The data pairs are displayed in the lookup<br />

table and used for the characteristic. You can modify the data when necessary. See also “Separate<br />

Component Characteristic” on page 297.<br />

� «Element Name»<br />

The characteristic of the MOS is defined by a characteristic component. Characteristic parameter<br />

type. Enter the name in the text box (e.g. XY1.VAL, EXP.VAL) or use the pin to connect<br />

the characteristic component. The internal used diode type is MOS.<br />

� � «Use pin»<br />

If the box is checked, the name is defined by the quantity connected to the pin, otherwise the<br />

name in the text box is used.<br />

«Control Signal»<br />

Defines the MOS control signal. Control parameter type. Enter a numerical value, a variable,<br />

or an expression in the text box or use the pin to connect a quantity.<br />

� � «Use pin»<br />

If the box is checked, the name is defined by the quantity connected to the pin, otherwise the<br />

name in the text box is used.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Characteristic; MOS CH real<br />

Control Signal; All components CTRL real<br />

Forward Voltage [V]; MOSEQUL VF real<br />

Bulk Resistance [Ω]; MOSEQUL RB real<br />

Reverse Resistance [Ω]; MOSEQUL/MOSEXP RR real<br />

Saturation Current [A]; MOSEXP ISAT real<br />

Thermal Voltage [V]; MOSEXP VT real<br />

Characteristic; MOSXY FILE file<br />

I<br />

vt () – Vf = --------------------- for v() t ≥ Vlimit R b<br />

vt ()<br />

I = --------- for v() t < Vlimit R r<br />

vt ()<br />

---------<br />

⎛ Vt ⎞<br />

it () = Is ⋅ ⎜e– 1⎟<br />

for v() t ≥ 0<br />

⎝ ⎠<br />

it ()<br />

vt ()<br />

=<br />

--------- for v() t < 0<br />

R r