Component Outputs<br />

Bipolar Junction Transistor<br />

<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 113<br />

Description [Unit] Parameter Name Data Type<br />

Voltage [V] V real<br />

Current [A] I real<br />

Conductivity [S] G real<br />

Derivative of Voltage [V/s] dV real<br />

Derivative of Current [A/s] dI real<br />

Component Nodes<br />

Description Node Name Nature<br />

Drain D electrical<br />

Source S electrical<br />

>>Basics>Circuit>Semiconductors System Level<br />

The System level BJT is used to simulate a static voltage-current-relation. Each voltage cause<br />

a corresponding current depending on the selected characteristic and the applied control signal.<br />

The BJT types of predefined characteristics defined within the component dialog guarantee<br />

a high calculation speed. In contrast to the predefined characteristic types (equivalent line,<br />

exponential function) you can use each other separate characteristic from the Tools folder or<br />

an appropriate quantity of a component. Usually an Equivalent line, Exponential function,<br />

Hyperbolic function, Polynom or the XY Lookup Table should be used. Characteristics based<br />

on XY-Data pairs allow simple access to measured curves for the switching behavior of the<br />

components.<br />

To control the BJT, a logical signal is applied. This signal can originate from any <strong>SIMPLORER</strong><br />

system variable.<br />

Control Signal (Base current) Component State<br />

> 0 ON<br />

≤ 0 OFF<br />

vt () =<br />

fit ( () , [ control signal]<br />

)<br />

Dialog Settings<br />

� «Characteristic Type»<br />

The BJT type with predefined characteristics is selected. In the list, select a characteristic.<br />

� «Type»<br />

In the list, select the equivalent line, exponential function, or XY Data Pairs and define the<br />

corresponding characteristic parameters. These are Common parameter types. Enter a numerical<br />

value, a variable, or an expression in the text box.