240 Modeling with Block Diagrams<br />

Dialog Settings<br />

«Value»<br />

Defines the absolute Value of the output amplitude. Common parameter type. Enter a numerical<br />

value, a variable, or an expression in the text box.<br />

� «Sample Time»<br />

Select «System» for simulator-defined variable sample time. Select «Value» to define a numerical<br />

value, a variable, or an expression in the text box or use the pin to connect a quantity.<br />

Please note: The sample time must be a positive value.<br />

� � «Use Pin»<br />

If the box is checked, the sample time is defined by the quantity connected to the pin, otherwise<br />

the value in the text box is used.<br />

«Input Signal»<br />

Enter a quantity name used in your model sheet in the text box to define the input signal<br />

(RLOAD.I, STEP.VAL, STATE.ST, VAR) or use the pin to connect a quantity. Please note: You<br />

cannot use conservative nodes from circuits as input signal (N0002, GND).<br />

� � «Use Pin»<br />

If the box is checked, the input signal is defined by the quantity connected to the pin, otherwise<br />

the value in the text box is used.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Absolute Value of Output Amplitude AMPL real<br />

Input Signal INPUT real<br />

Sample Time [s] TS real<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Block output signal VAL real