Component Outputs<br />

Mutual Inductance<br />

<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 83<br />

Description [Unit] Parameter Name Data Type<br />

Voltage [V] V real<br />

Current [A] I real<br />

Derivative of Voltage [V/s] dV real<br />

Derivative of Current [A/s] dI real<br />

Component Nodes<br />

Description Node Name Nature<br />

Pin 1 (with red point) N1 electrical<br />

Pin 2 N2 electrical<br />

>>Basics>Circuit>Passive Elements<br />

The component represents the mutual coupling between two inductors, L1 and L2, quantitatively<br />

determined by the factor k.<br />

The mutual inductance is equivalent to the present value of the quantity specified in the text<br />

box. For the quantity any numerical value, variable, mathematical or logical expression can<br />

be used. Usually a Constant value, a Time function or a variable are chosen, or the value of<br />

the inductance is determined in a state graph. A mathematical expression must conform to<br />

the syntax of the <strong>SIMPLORER</strong> expression interpreter. All system quantities and variables can<br />

be combined with mathematical and logical operators and constants.<br />

However, if the value of this quantity is unstable, numerical problems can occur. In particular,<br />

sudden changes in the first derivation of the control quantity should be avoided.<br />

M = K⋅L1⋅L2 with K =<br />

K1 ⋅ K2 Dialog Settings<br />

«Inductance L1/L2 [H]»<br />

L1 and L2 hold the names of coupled inductances. Quantity parameter type. The type accepts<br />

only an inductance parameter (e.g. L1.L, Name.L). The values cannot be assigned by a variable.<br />

Enter the quantity of a inductance or use the pin to connect the quantity.<br />

� � «Use pin»<br />

If the box is checked, the inductances are defined by the quantity connected to the pin, otherwise<br />

the value in the text box is used.<br />

«Mutual Inductance»<br />

K/M is the factor which quantitatively determines the mutual inductances. Common parameter<br />

type. Enter a numerical value, a variable, or an expression in the text box or use the pin<br />

to connect a quantity.<br />

� � «Use pin»<br />

If the box is checked, the coupling factor or M is defined by the quantity connected to the pin,<br />

otherwise the value in the text box is used.