9<br />

298 Modeling Tools<br />

Requirements for Characteristic Blocks<br />

• a physically useful characteristic for each parameter value (for voltage '0' is also current<br />

'0', otherwise errors occur during simulation)<br />

• the same sequence of monotonously increased or decreased values for the X axis<br />

• a constant select parameter value (Y axis) for each block<br />

• across all blocks the select parameter must be monotonously increased or decreased.<br />

Z<br />

Using 3D Lookup Tables with Components<br />

X Z Y<br />

0 0 0<br />

1 1 0<br />

2 2 0<br />

0 0 1<br />

1 2 1<br />

2 4 1<br />

0 0 2<br />

1 3 2<br />

2 6 2<br />

Open the property dialog of a nonlinear component, for example of a resistor. Select «Nonlinear»<br />

in the dialog and click . Enter the name of the 3D Lookup Table component<br />

in the text box (Name.VAL, for example Werte3D501.VAL). You cannot use the pin<br />

function with the 3D Lookup Table.<br />

During simulation, the current values of the nonlinear component are available for X,Y, and Z<br />

value in the 3D Lookup Table component. If you define outputs, you can display these quantities.<br />

Components Using Characteristics<br />

The table shows <strong>SIMPLORER</strong>’s interpretation of the corresponding values of nonlinear components.<br />

The X, Y, and Z axis are interpreted as follows:<br />

Component Description x-Axis<br />

1. Channel<br />

See also 3.4 “Characteristics in Simulation Models” on page 55.<br />

Y<br />

X<br />

1. Block<br />

Characteristic for value 0 (Y)<br />

2. Block<br />

Characteristic for value 1 (Y)<br />

3. Block<br />

Characteristic for value 2 (Y)<br />

z-Axis<br />

2. Channel<br />

y-Axis<br />

3. Channel<br />

RNL nonlinear resistance voltage v [V] current i [A] Parameter<br />

GVNL nonlinear conductance current i [A] voltage v [V] Parameter<br />

LNL nonlinear inductance flux Ψ [Vs] current i [A] Parameter<br />

LINL nonlinear dual inductance current i [A] inductance L [H] Parameter<br />

CNL nonlinear capacitance charge Q [As] voltage v [V] Parameter<br />

CVNL nonlinear dual capacitance voltage v [V] capacitance C [F] Parameter<br />

Dialog Settings<br />

«Parameter Variable»<br />

The variable value selects one of the defined characteristic blocks. Enter a variable name in<br />

the text box. The range of the values must be available in the characteristic file; otherwise,<br />

incorrect values are used.