13<br />

412 Simulator<br />

13.4.1 Displaying Monitors<br />

After starting a simulation, you can display the simulator state monitor. The monitor offer a<br />

variety of information about the simulation’s progress, especially if graphic outputs in the<br />

View Tool or Display Elements are not being used, to reduce calculation time.<br />

Choose «Simulation Monitor» on the simulator. Start the simulator menu either with the Windows<br />

taskbar icon or with the simulation toolbar command ).<br />

Displaying the Simulator State Monitor<br />

The simulator state monitor shows the name of the simulation source file being processed, the<br />

calculation progress, the start and stop time of simulation, and the duration of the simulation,<br />

as well as active simulation parameters. The dialog text box shows those outputs generated<br />

by the DIS and TXT functions (actions) of the user’s state graph.<br />

Click the icons and , and the simulation can be stopped temporarily and resumed.<br />

Displaying the Circuit Simulator Monitor<br />

The monitor for the circuit simulator is available only when circuit components belong to the<br />

simulation model. The circuit simulator monitor shows the simulation parameter of circuit<br />

simulator and the curve of iterations during the simulation. The active number of iterations is<br />

an important feature to evaluate simulation results. The number should be clear lower than<br />

the defined maximum for iterations. When the number of iterations is a time at the upper limit,<br />

decrease the simulation time step or increase the number of iterations.<br />

13.4.2 Using Simulator Files<br />

The simulator is able to create two files with data at a certain moment of simulation:<br />

• A simulator state file with all values at a specific simulation time (.krn)<br />

• A file with the active values of capacitors and inductor (.aws)<br />

Both files can be used to start a simulation with predefined quantities for initial values of capacitors<br />

and inductors (initial values) or for the complete simulation model (simulator state).<br />

If one of these files is created at a time a message is written in the Information window.<br />

Settings in the SSC Commander for Simulator Files<br />

To simulate with initial values and<br />

state files, the corresponding files<br />

must be created after the simulation.<br />

These files can be created manually<br />

or automatically.<br />

The handling of state or initial value<br />

files depends on the settings made in<br />

the SSC Commander OPTIONS>SIMU-<br />

LATOR SETTINGS or in the Simulator<br />

Toolbar menu.<br />

Dialog box simulator settings