<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 403<br />

• Spice compatible models<br />

• Transformers<br />

• Continuous Blocks<br />

• Discrete Blocks<br />

• Source Blocks<br />

• Signal Processing Blocks<br />

(except for MAX, MIN, MAXT, MINT, two-point element with hysteresis)<br />

• Math Blocks<br />

• Measurement (Electrical domain)<br />

• Time Functions<br />

• Characteristics<br />

• Equations (except for DES solver)<br />

• C models with definition for DC simulation.<br />

• VHDL-AMS models with definition for DC simulation.<br />

• Macros using appropriate models (internal components, C models)<br />

Not supported components for DC simulation in the «Basics» tab:<br />

• Electrical machines<br />

• State graph components<br />

• Signal Characteristics<br />

• Physical Domain Components<br />

Not supported components for DC simulation in the other tabs:<br />

• Components in the «AMS» tab<br />

• Components in the «Digital» tab<br />

• Components in the «Tools» tab<br />

If models without DC implementation are used in an DC simulation, an error message appears.<br />

To leave components without DC implementation on the sheet, select the components<br />

and choose ELEMENT>DON’T ADD TO MODEL DESCRIPTION. When you want to process a transient<br />

simulation, you can change this option.<br />

DC Simulation Models<br />

In addition to invalid network configurations, the following configurations cannot be used<br />

with DC simulations:<br />

• Parallel connection of voltage sources and inductances<br />

• Parallel connection of current sources and capacitances without any other branch<br />

See also “Network Configurations” on page 71.<br />

Parameters of DC Simulator<br />

In the Schematic, choose SIMULATION>PARAMETER and click the «DC» tab to set the parameters<br />

for the DC simulator.<br />

Solver Parameters<br />

THETA (23) Global ambient temperature for temperature dependent components<br />

[°C].