<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 93<br />

«Early Voltage [V]»/«Collector-Emitter potential [V]»<br />

Parameters of the Collector current source. Common parameter types. Enter a numerical value,<br />

a variable, or an expression in the text box or use the pin to connect a quantity.<br />

Linear voltage/current controlled Current Source<br />

it () = K ⋅ v[ control component]<br />

it () = K ⋅ i[ control component]<br />

The value of the source current is calculated from the voltage/current of the controlling circuit<br />

component multiplied by an arbitrary control coefficient K. For the control, any circuit component<br />

can be specified.<br />

In <strong>SIMPLORER</strong> only voltage sources or ammeters are allowed as controlling components for<br />

current controlled elements. These must be inserted properly in the controlling branch.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Control Quantity [V or A] QUANT real<br />

Factor [/] FACT real<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Voltage [V] V real<br />

Current [A] I real<br />

Derivative of Voltage [V/s] dV real<br />

Derivative of Current [A/s] dI real<br />

Component Nodes<br />

Description Node Name Nature<br />

Pin 1 (with red point) N1 electrical<br />

Pin 2 N2 electrical<br />

Nonlinear voltage/current-controlled Current Source<br />

it () = f( v[ control component]<br />

)<br />

it () =<br />

f( i[ control component]<br />

)<br />

The value of the source current is calculated from the voltage/current of the controlling component<br />

corresponding to an arbitrary nonlinear function. The control can result from any component<br />

of the electrical circuit.<br />

To describe the nonlinear relation, you must specify a name of an appropriate XY nonlinear<br />

characteristic function. See also “Separate Component Characteristic” on page 297.<br />

X-value: control voltage/current (independent quantity<br />

Y-value: source current (dependent quantity)