<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 299<br />

� «Interpolation»<br />

In the list, select «Linear» or «Spline». Within the characteristic the values are interpolated;<br />

outside the values are extrapolated. The spline interpolation is only available if the X and Y<br />

value is at least 4 points away from the limit. Therefore, the spline interpolation is useful only<br />

if the characteristic has more than 8x8 data points. If the characteristic is smaller than 8x8,<br />

linear interpolation is used, even if spline interpolation is defined.<br />

� «File Name»<br />

If no file is used, enter the datasets in the tables. Create, delete, or move entries with the symbols<br />

placed on the upper right side. See also “Defining Parameters” on page 49.<br />

� «File Name»<br />

To define the data points, a three-dimensional data file is used which can be created by the<br />

DAY Post Processor or a text editor. The XZY data file always has three channels (columns)<br />

where X, Y, and Z value are stored. The length (number of lines) of the data files is arbitrary.<br />

To open or save files, click the symbols next to the text box. Please note: Select the correct file<br />

filter (.mdx) before browsing. See also “The .mdx File Format” on page 467.<br />

� � «Unit X Axis»«Unit Y Axis»«Unit Z Axis»<br />

Defines the units for X, Y, and Z Axis. Check the options and enter the unit in the text box.<br />

The units are saved in the created .mdx file.<br />

«X Axis»<br />

Defines the X values of the each characteristic block. Create, delete, or move entries with the<br />

symbols placed on the upper right side. If you click , you can sweep data for<br />

a given range of values. replaces the values in the lookup table, inserts<br />

the new data at the table end.<br />

«Y Axis»<br />

Defines the select value of the characteristic block. The value is taken from the value of the<br />

parameter variable.<br />

Create, delete, or move entries with the symbols placed on the upper right side and enter a<br />

numerical values in the table. If you click , you can sweep data for a given<br />

range of values. replaces the values in the lookup table, inserts the new<br />

data at the table end.<br />

«Z Axis»<br />

Defines the Z values for each X value. Click a Y value in the mid-table. All available X values<br />

are displayed in the right table. Click in the «Z axis» field and enter a numerical value. See<br />

also requirements for characteristic blocks.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Interpolation Method, 1-linear, 2-spline Interpolation real<br />

Variable Name of Select Parameter FamilyParameter real<br />

File Name, 3-dimensional .mdx File FamilyOfCurves file<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Value VAL real<br />

Current X, Y, Z Values of the Nonlinear Component X, Y, Z real